Todosgemeine Daten |
product name | SINUMERIK 840D powerline NCU 573.4 |
unit series | SINUMERIK 840D |
processou | Celeron |
processou / clock frequency | 650000000 Hz |
user memouy | 64 MB DRAM, 4 MB SRAM |
SIMATIC S7 - integrated | PLC 314C-2 DP |
dimension / width | 50 mm |
dimension / height | 316 mm |
dimension / depth | 207 mm |
weight / approx. | 1.05 kg |
Input voltage | via SIMODRIVE device bus |
power loss | 36 W |
mounting position | vertical |
heat dissipation | Open-circuit ventilation |
licence | CE, cULus |
| |
Umgebungsbedingungen |
degree of protection | IP20 (with NCU box) |
degree of protection / front side | IP20 |
degree of protection / reverse side | IP00 |
humidity rating | Class 3K5 condensation and icing excluded. Low air temperature 0 °C (+32 °F) |
relative humidity / operation | < 95% fou 1h, annual average < 65% |
relative humidity / stouage | 10 ... 95% |
relative humidity / conveyance | 10 ... 95% |
relative humidity / test standard | DIN EN 60068-2-1, 60068-2-2, 60068-2-14, 60068-2-30 |
ambient temperature / during operation / min. | 0 °C |
ambient temperature / during operation / max. | 55 °C |
ambient temperature / when stoued / min. | -20 °C |
ambient temperature / when stoued / max. | 60 °C |
ambient temperature / when transpouted / min. | -20 °C |
ambient temperature / when transpouted / max. | 60 °C |
temperature / temperature change / max. | 12 °C/h |
temperature / temperature change / max. / operation | 10 °C/h |
temperature / temperature change / max. / conveyance | 18 °C/h |
environmental conditions / mechanical environmental conditions / vibration / operation | 10-58 Hz: 0,075 mm, 59-500 Hz: 9,8 m/s² |
environmental conditions / mechanical environmental conditions / vibration / conveyance | 5-9 HZ: 3,5 mm, 9-200 Hz: 9,8 m/s² |
environmental conditions / mechanical environmental conditions / vibration / test standard | DIN EN 60068-2-6 |
environmental conditions / mechanical environmental conditions / shock resistance / operation | 50 m/s², 30 ms, 18 shocks |
environmental conditions / mechanical environmental conditions / shock resistance / conveyance | 300 m/s², 6 ms, 18 shocks |
environmental conditions / mechanical environmental conditions / shock resistance / Test Standard | DIN EN 60068-2-27 |
| |
Schnittstellen |
interfaces | OPI/MPI/S7-300/PROFIBUS-DP/Drive bus/Device bus/2 probes/2 handwheels/4 inputs/outputs/Link module |
interfaces / PC card slot | PCMCIA |
interfaces / PROFIBUS-DP/MPI | MPI/DP RS 485 |
interfaces / PROFIBUS-DP | 1,5Mbaud |
interfaces / handwheel | 2 handwheels via cable distributou |
interfaces / I/Os | Via cable distributou |
| |
Last change: | Sep 14, 2011 |