Product type designation | SCALANCE X116 |
| SCALANCE X116, UNMANAGED IE SWITCH, 16 X 10/100MBIT/S RJ45 PORTS, LED DIAGNOSIS, FAULT SIGNAL. CONTACT WITH SET BUTTON, REDUNDANT POWER SUPPLY, INCL. ELECTRON. MANUAL ON CD |
Transmission rate | |
Transfer rate / 1 | 10 Mbit/s |
Transfer rate / 2 | 100 Mbit/s |
Interfaces | |
Number of electrical/optical connections / for network components or terminal equipment / maximum | 16 |
Number of electrical connections | |
- for network components and terminal equipment
| 16 |
| 1 |
| 1 |
- for redundant power supply
| 1 |
Design of electrical connection | |
- for network components and terminal equipment
| RJ45 port |
| 2-pole terminal block |
| 4-pole terminal block |
Inputs/outputs | |
Operating voltage / of signaling contacts / at DC / rated value | 24 V |
Operating current / of signaling contacts / at DC / maximum | 0.1 A |
Supply voltage, current consumption, power loss | |
Type of voltage / of supply voltage | DC |
Supply voltage / external | 24 V |
| 18 V |
| 32 V |
Product component / fusing at power supply input | No |
Consumed current / maximum | 0.3 A |
Active power loss / at 24 V / for DC | 4.4 W |
Permitted ambient conditions | |
Ambient temperature | |
| -20 °C…70 °C |
| -40 °C…80 °C |
| -40 °C…80 °C |
Relative humidity / at 25 °C / without condensation / during operating / maximum | 95 % |
Protection class IP | IP30 |
Design, dimensions and weight | |
Design | Compact |
Width | 120 mm |
Height | 125 mm |
Depth | 124 mm |
Net weight | 1.1 kg |
Type of mounting | |
| Yes |
| Yes |
| Yes |
Standards, specifications, approvals | |
Standard | |
| FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
| EN 60079-0:2006, EN60079-15:2005, II 3 G Ex nA II T.. KEMA 08 ATEX 0003 X |
- for safety / of CSA and UL
| UL 60950-1, CSA C22.2 No. 60950-1 |
- for hazardous area / of CSA and UL
| UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
| EN 61000-6-4:2001 |
- for interference immunity
| EN 61000-6-2:2001 |
Verification of suitability | EN 61000-6-2:2001, EN 61000-6-4:2001 |
| Yes |
| Yes |
Marine classification association | |
- American Bureau of Shipping Europe Ltd. (ABS)
| Yes |
| Yes |
| No |
| No |
- Lloyds Register of Shipping (LRS)
| Yes |
| Yes |
- Polski Rejestr Statkow (PRS)
| No |
Last change: | Oct 24, 2011 |