Product type designation | SCALANCE X106-1 |
| SCALANCE X106-1, UNMANAGED IE SWITCH, 6 X 10/100MBIT/S RJ45 PORTS, 1 X 100 MBIT/S MULTIMODE BFOC, LED DIAGNOSTICS, FAULT SIGNAL. CONTACT WITH SET BUTTON, REDUNDANT VOLTAGE SUPPLY, W. ELECTRONIC MANUALS ON CD |
Transmission rate | |
Transfer rate / 1 | 10 Mbit/s |
Transfer rate / 2 | 100 Mbit/s |
Interfaces | |
Number of electrical/optical connections / for network components or terminal equipment / maximum | 7 |
Number of electrical connections | |
- for network components and terminal equipment
| 6 |
| 1 |
| 1 |
- for redundant power supply
| 1 |
Design of electrical connection | |
- for network components and terminal equipment
| RJ45 port |
| 2-pole terminal block |
| 4-pole terminal block |
Number of optical interfaces / for optical waveguide | |
| 1 |
Design of optical interface / for optical waveguide | |
| BFOC sockets (multimode up to 5 km) |
Connectable optical power relative to 1 mW | |
- of the transmitter output
| -19 dB…-14 dB |
- of the receiver input / maximum
| -14 dB |
Optical sensitivity relative to 1 mW / of the receiver input / minimum | -32 dB |
Attenuation / of fiber-optic cable transmission link / minimum necessary | 0 dB |
Range / at the optical interface / depending on the optical fiber used | 0 km…5 km |
Inputs/outputs | |
Operating voltage / of signaling contacts / at DC / rated value | 24 V |
Operating current / of signaling contacts / at DC / maximum | 0.1 A |
Supply voltage, current consumption, power loss | |
Type of voltage / of supply voltage | DC |
Supply voltage / external | 24 V |
| 18 V |
| 32 V |
Product component / fusing at power supply input | Yes |
Consumed current / maximum | 0.15 A |
Active power loss / at 24 V / for DC | 3.6 W |
Permitted ambient conditions | |
Ambient temperature | |
| -10 °C…60 °C |
| -40 °C…80 °C |
| -40 °C…80 °C |
Relative humidity / at 25 °C / without condensation / during operating / maximum | 95 % |
Protection class IP | IP30 |
Design, dimensions and weight | |
Design | Compact |
Width | 60 mm |
Height | 125 mm |
Depth | 124 mm |
Net weight | 0.78 kg |
Type of mounting | |
| Yes |
| Yes |
| Yes |
Standards, specifications, approvals | |
Standard | |
| FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T.. |
| EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X |
- for safety / of CSA and UL
| UL 60950-1, CSA C22.2 No. 60950-1 |
- for hazardous area / of CSA and UL
| UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T.. |
| EN 61000-6-4 (Class A) |
- for interference immunity
| EN 61000-6-2 |
Verification of suitability | EN 61000-6-2, EN 61000-6-4 |
| Yes |
| Yes |
Marine classification association | |
- American Bureau of Shipping Europe Ltd. (ABS)
| Yes |
| Yes |
| Yes |
| Yes |
- Lloyds Register of Shipping (LRS)
| Yes |
| Yes |
- Polski Rejestr Statkow (PRS)
| Yes |
Last change: | Oct 24, 2011 |