6ES7314-6EH04-0AB0 CPU314C-2PN/DP, 24DI/16DO/4AI/2AO, 192KB

Manufacturer:
SIEMENS
Weight:
0.68kg
Product Range:
Automation Systems

Product Information

SIMATIC S7-300, CPU 314C-2PN/DP COMPACT CPU WITH 192 KBYTE WORKING MEMORY, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, INTEGRATED 24V DC POWER SUPPLY, FRONT CONNECTOR (2 X 40PIN) AND MICRO MEMORY CARD REQUIRED
General information
Hardware product version01
Firmware versionV3.3
[nicht versorgt: TAK_ABW067_001_000]
associated programming packageSTEP7 V5.5 or higher with HSP191
Supply voltage
24 V DCYes
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
External protection for supply cables (recommendation)Miniature circuit breaker, type C; min 2 A; miniature circuit breaker type B, min. 4 A
Mains buffering
Mains/voltage failure stored energy time5 ms
Repeat rate, min.1 s
Digital inputs
Load voltage L+
Rated value (DC)24 V
Reverse polarity protectionYes
Digital outputs
Load voltage L+
Rated value (DC)24 V
Reverse polarity protectionNo
Input current
Current consumption (rated value)850 mA
Current consumption (in no-load operation), typ.190 mA
Inrush current, typ.5 A
I²t0.7 A²·s
from supply voltage L+, max.850 mA
Digital inputs
from load voltage L+ (without load), max.80 mA
Digital outputs
from load voltage L+, max.50 mA
Power losses
Power loss, typ.14 W
Memory
Work memory
integrated192 Kibyte
expandableNo
Size of retentive memory for retentive data blocks64 Kibyte
Load memory
pluggable (MMC)Yes
pluggable (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 a
Backup
presentYes; Guaranteed by MMC (maintenance-free)
without batteryYes; Program and data
CPU processing times
for bit operations, min.0.06 µs
for word operations, min.0.12 µs
for fixed point arithmetic, min.0.16 µs
for floating point arithmetic, min.0.59 µs
CPU-blocks
Number of blocks (total)1024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.1024; Number range: 1 to 16000
Size, max.64 Kibyte
FB
Number, max.1024; Number range: 0 to 7999
Size, max.64 Kibyte
FC
Number, max.1024; Number range: 0 to 7999
Size, max.64 Kibyte
OB
Descriptionsee instruction list
Size, max.64 Kibyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of time interrupt OBs4; OB 32, 33, 34, 35
Number of process alarm OBs1; OB 40
Number of DPV1 alarm OBs3; OB 55, 56, 57
Number isochronous mode OBs1; OB 61; only for PROFINET
Number of startup OBs1; OB 100
Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class16
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number256
Retentivity
adjustableYes
lower limit0
upper limit255
presetZ 0 to Z 7
Counting range
adjustableYes
lower limit0
upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number256
Retentivity
adjustableYes
lower limit0
upper limit255
presetNo retentivity
Time range
lower limit10 ms
upper limit9990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area, totalAll, max. 64 KB
Flag
Number, max.256 byte
Retentivity availableYes; MB 0 to MB 255
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Number, max.1024; Number range: 1 to 16000
Size, max.64 Kibyte
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Local data
per priority class, max.32 Kibyte; Max. 2048 bytes per block
Address area
I/O address area
Inputs2048 byte
Outputs2048 byte
of which, distributed
Inputs2003 byte
Outputs2010 byte
Process image
Inputs2048 byte
Outputs2048 byte
Inputs, adjustable2048 byte
Outputs, adjustable2048 byte
Inputs, default256 byte
Outputs, default256 byte
Default addresses of the integrated channels
Digital inputs136.0 to 138.7
Digital outputs136.0 to 137.7
Analog inputs800 to 809
Analog outputs800 to 803
Subprocess images
Number of subprocess images, max.1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels
Inputs16048
Outputs16096
Inputs, of which central1016
Outputs, of which central1008
Analog channels
Inputs1006
Outputs1007
Inputs, of which central253
Outputs, of which central250
Hardware configuration
Racks, max.4
Modules per rack, max.8; In rack 3 max. 7
Expansion devices, max.3
Number of DP masters
integrated1
via CP4
Number of operable FMs and CPs (recommended)
FM8
CP, point-to-point8
CP, LAN10
Time of day
Clock
Hardware clock (real-time clock)Yes
battery-backed and synchronizableYes
Deviation per day, max.10 s; Typ.: 2 s
Backup time6 wk; At 40 °C ambient temperature
Behavior of the clock following POWER-ONClock continues running after POWER OFF
Behavior of the clock following expiry of backup periodClock continues to run with the time at which the power failure occurred
Operating hours counter
Number1
Number/Number range0
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 hour
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
to DP, masterYes; With DP slave only slave clock
to DP, slaveYes
in AS, masterYes
in AS, slaveYes
on Ethernet via NTPYes; as client
Digital inputs
Number/binary inputs24
of which, inputs usable for technological functions16
integrated channels (DI)24
Input characteristic curve acc. to IEC 1131, Type 1Yes
Number of simultaneously controllable inputs
horizontal installation
up to 40 °C, max.24
up to 60 °C, max.12
vertical installation
up to 40 °C, max.12
Technological functions
shielded, max.50 m; at maximum count frequency
Unshielded, max.not allowed
Standard DI
shielded, max.1000 m
Unshielded, max.600 m
Input voltage
Type of voltage / of the input voltage
Rated value, DC24 V
for signal "0"-3 to +5 V
for signal "1"15 to 30 V
Input current
for signal "1", typ.8 mA
Input delay (for rated value of input voltage)
for standard inputs
ParameterizableYes; 0.1 / 0.3 / 3 / 15 ms (You can reconfigure the input delay of the standard inputs during program runtime. Please note that under certain circumstances your newly set filter time may not be effective until the next filter cycle.)
Rated value3 ms
for counter/technological functions
at "0" to "1", max.8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency
Cable length
Cable length, shielded, max.1000 m; 50 m for technological functions
Cable length unshielded, max.600 m; For technological functions: No
Digital outputs
Number/binary outputs16
of which high-speed outputs4; Notice: You cannot connect the fast outputs of your CPU in parallel
integrated channels (DO)16
Functionality/short-circuit strengthYes; Clocked electronically
Response threshold, typ.1 A
Limitation of inductive shutdown voltage toL+ (-48 V)
Lamp load, max.5 W
Controlling a digital inputYes
Output voltage
for signal "1", min.L+ (-0.8 V)
Output current
for signal "1" rated value500 mA
for signal "1" permissible range, min.5 mA
for signal "1" permissible range, max.0.6 A
for signal "1" minimum load current5 mA
for signal "0" residual current, max.0.5 mA
Parallel switching of 2 outputs
for increased powerNo
for redundant control of a loadYes
Switching frequency
with resistive load, max.100 Hz
with inductive load, max.0.5 Hz
on lamp load, max.100 Hz
of the pulse outputs, with resistive load, max.2.5 kHz
Aggregate current of outputs (per group)
horizontal installation
up to 40 °C, max.3 A
up to 60 °C, max.2 A
vertical installation
up to 40 °C, max.2 A
Load resistance range
lower limit48 Ω
upper limit4 kΩ
Cable length
Cable length, shielded, max.1000 m
Cable length unshielded, max.600 m
Analog inputs
Integrated channels (AI)5; 4 x current/voltage, 1 x resistance
Number of analog inputs for voltage/current measurement4
Number of analog inputs for resistance/temperature measurement1
permissible input frequency for current input (destruction limit), max.5 V; Permanent
permissible input voltage for voltage input (destruction limit), max.30 V; Permanent
permissible input current for voltage input (destruction limit), max.0.5 mA; Permanent
permissible input current for current input (destruction limit), max.50 mA; Permanent
Technical unit for temperature measurement adjustableYes; Degrees Celsius / degrees Fahrenheit / Kelvin
Input ranges
VoltageYes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ
CurrentYes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω
Resistance thermometerYes; Pt 100 / 10 MΩ
ResistanceYes; 0 Ω to 600 Ω / 10 MΩ
Input ranges (rated values), voltages
0 to +10 VYes
Input resistance (0 to 10 V)100 kΩ
Input ranges (rated values), currents
0 to 20 mAYes
Input resistance (0 to 20 mA)100 Ω
-20 to +20 mAYes
Input resistance (-20 to +20 mA)100 Ω
4 to 20 mAYes
Input resistance (4 to 20 mA)100 Ω
Input ranges (rated values), resistance thermometers
Pt 100Yes
Input resistance (Pt 100)10 MΩ
Input ranges (rated values), resistors
No-Load voltage, typ.3.3 V
Measured current, typ.1.25 mA
0 to 600 ohmsYes
Input resistance (0 to 600 ohms)10 MΩ
Resistance thermometer (RTD)
Characteristic linearization
for resistance thermometerPt 100
Characteristic linearization
ParameterizableYes; by software
Temperature compensation
ParameterizableNo
Cable length
Cable length, shielded, max.100 m
Analog outputs
Number of analog outputs2
Integrated channels (AO)2
Voltage output, short-circuit protectionYes
Voltage output, short-circuit current, max.55 mA
Current output, no-load voltage, max.14 V
Output ranges, voltage
0 to 10 VYes
-10 to +10 VYes
Output ranges, current
0 to 20 mAYes
-20 to +20 mAYes
4 to 20 mAYes
Connection of actuators
for voltage output 2-conductor connectionYes; Without compensation of the line resistances
for voltage output 4-conductor connectionNo
for current output 2-conductor connectionYes
Load impedance (in rated range of output)
with voltage outputs, min.1 kΩ
with voltage outputs, capacitive load, max.0.1 µF
with current outputs, max.300 Ω
with current outputs, inductive load, max.0.1 mH
Destruction limits against externally applied voltages and currents
Voltages at the outputs towards MANA16 V; Permanent
Current, max.50 mA; Permanent
[nicht versorgt: TAK_ABT299_001_000]
Cable length, shielded, max.200 m
Analog value creation
Measurement principleActual value encryption (successive approximation)
Integrations and conversion time/ resolution per channel
Resolution with overrange (bit including sign), max.12 bit
Integration time, parameterizableYes; 16.6 / 20 ms
permissible input frequency, max.400 Hz
Interference voltage suppression for interference frequency f1 in Hz60 / 50 Hz
Conversion time (per channel)1 ms
Time constant of the input filter0.38 ms
Basic execution time of the module (all channels released)1 ms
Settling time
for resistive load0.6 ms
for capacitive load1 ms
for inductive load0.5 ms
Encoder
Connection of signal encoders
for voltage measurementYes
for current measurement as 2-wire transducerYes; with external supply
for current measurement as 4-wire transducerYes
for resistance measurement with 2-conductor connectionYes; Without compensation of the line resistances
for resistance measurement with 3-conductor connectionNo
for resistance measurement with 4-conductor connectionNo
Connectable encoders
2-wire BEROSYes
permissible quiescent current (2-wire BEROS), max.1.5 mA
Errors/accuracies
Temperature error (relative to input area)+/- 0,006 %/K
Crosstalk between the inputs, min.60 dB
Repeat accuracy in settled status at 25 °C (relative to input area)+/- 0,06 %
Output ripple (based on output area, bandwidth 0 to 50 kHz)+/- 0,1 %
Linearity error (relative to output area)+/- 0,15 %
Temperature error (relative to output area)+/- 0,01 %/K
Crosstalk between the outputs, min.60 dB
Repeat accuracy in settled status at 25 °C (relative to output area)+/- 0,06 %
Operational limit in overall temperature range
Voltage, relative to input area+/- 1 %
Current, relative to input area+/- 1 %
Impedance, relative to input area+/- 1 %
Voltage, relative to output area+/- 1 %
Current, relative to output area+/- 1 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to input area+/- 0,8 %; Linearity error +/- 0.06 %
Current, relative to input area+/- 0,8 %; Linearity error +/- 0.06 %
Impedance, relative to input area+/- 0,8 %; Linearity error +/- 0.2%
Resistance-type thermometer, relative to input area+/- 0,8 %
Voltage, relative to output area+/- 0,8 %
Current, relative to output area+/- 0,8 %
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency
Series mode interference (peak value of interference < rated value of input range), min.30 dB
Common mode interference, min.40 dB
Interfaces
Number of USB interfaces0
Number of parallel interfaces0
Number of 20 mA interfaces (TTY)0
Number of RS 232 interfaces0
Number of RS 422 interfaces0
Number of other hardware interfaces1; Ethernet, 2-port switch, 2*RJ45
1st interface
Type of interfaceIntegrated RS 485 interface
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.200 mA
Functionality
MPIYes
DP masterYes
DP slaveYes
Point-to-point connectionNo
MPI
Services
PG/OP communicationYes
RoutingYes
Global data communicationYes
S7 basic communicationYes
S7 communicationYes
S7 communication, as clientNo; (but via CP and loadable FBs)
S7 communication, as serverYes
Transmission rate, max.12 Mbit/s
DP master
Services
PG/OP communicationYes
RoutingYes
Global data communicationNo
S7 basic communicationYes; (I blocks only)
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes
Equidistance mode supportYes
Isochronous modeNo
SYNC/FREEZEYes
Activation/deactivation of DP slavesYes
Number of DP slaves that can be simultaneously activated/deactivated, max.8
Direct data exchange (slave-to-slave communication)Yes; As subscriber
DPV1Yes
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.124
Address area
Inputs, max.2 Kibyte
Outputs, max.2 Kibyte
User data per DP slave
Inputs, max.244 byte
Outputs, max.244 byte
DP slave
Services
PG/OP communicationYes
RoutingYes; Only with active interface
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes; Connection configured on one side only
Direct data exchange (slave-to-slave communication)Yes
DPV1No
Transmission rate, max.12 Mbit/s
Automatic baud rate searchYes; only with passive interface
Transfer memory
Inputs244 byte
Outputs244 byte
Address area, max.32
User data per address area, max.32 byte
2nd interface
Type of interfacePROFINET
PhysicsEthernet RJ45
IsolatedYes
Integrated switchYes
Number of ports2
Automatic detection of transmission speedYes; 10/100 Mbit/s
AutonegotiationYes
AutocrossingYes
Media redundancy
supportedYes
Switchover time on line break, typically200 ms; PROFINET MRP
Number of stations in the ring, max.50
Change of IP address at runtime, supportedYes
Functionality
MPINo
DP masterNo
DP slaveNo
PROFINET IO ControllerYes; Also simultaneously with IO-Device functionality
PROFINET IO DeviceYes; Also simultaneously with IO Controller functionality
PROFINET CBAYes
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Web serverYes
Number of HTTP clients5
PROFINET IO Controller
Services
PG/OP communicationYes
RoutingYes
S7 communicationYes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32
Isochronous modeYes; OB 61
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Transmission rate, max.100 Mbit/s
Number of connectable IO devices, max.128
Max. number of connectable IO devices for RT128
of which in line, max.128
Number of IO devices with IRT and the option "high flexibility"128
of which in line, max.61
Number of IO Devices with IRT and the option "high performance", max.64
of which in line, max.64
IRT, supportedYes
Shared device, supportedYes
Prioritized startup supportedYes
Number of IO Devices, max.32
Activation/deactivation of IO DevicesYes
Number of IO Devices that can be simultaneously activated/deactivated, max.8
IO Devices changing during operation (partner ports), supportedYes
Max. number of IO devices per tool8
Device replacement without swap mediumYes
Send cycles250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
Updating time250 µs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, Technical Data" for more details)
Address area
Inputs, max.2 Kibyte
Outputs, max.2 Kibyte
User data per address area, max.
User data consistency, max.1024 byte
PROFINET IO Device
Services
PG/OP communicationYes
RoutingYes
S7 communicationYes; With loadable FBs, max. configurable connections: 10, max. number of instances: 32
Isochronous modeNo
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
IRT, supportedYes
PROFIenergy, supportedYes; With SFB 73 / 74 prepared for loadable