SIMATIC S7-1200, ANALOG OUTPUT, SM 1232, 4 AO, +/-10V, 14 BIT RESOLUTION, OR 0-20 MA, 13 BIT RESOLUTION, |
Supply voltage |
24 V DC | Yes |
Input current |
Current consumption, typ. | 45 mA |
from backplane bus 5 V DC, typ. | 80 mA |
Power losses |
Power loss, typ. | 1.5 W |
Analog inputs |
Temperature compensation |
Parameterizable | No |
Analog outputs |
Number of analog outputs | 4; Current or voltage |
Output ranges, voltage |
-10 to +10 V | Yes |
Output ranges, current |
0 to 20 mA | Yes |
Load impedance (in rated range of output) |
with voltage outputs, min. | 1000 Ω |
with current outputs, max. | 600 Ω |
Analog value creation |
Measurement principle | Differential |
Integrations and conversion time/ resolution per channel |
Resolution (incl. overrange) | Voltage: 14 bits; Current : 13 bits |
Integration time, parameterizable | Yes |
Interference voltage suppression for interference frequency f1 in Hz | 40 dB, DC to 60 V for interference frequency 50 / 60 Hz |
Errors/accuracies |
Temperature error (relative to output area) | 25 °C ±0.3% to 55 °C ±0.6% total measurement range |
Basic error limit (operational limit at 25 °C) |
Voltage, relative to output area | +/- 0,3 % |
Current, relative to output area | +/- 0,3 % |
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency |
common mode voltage, max. | 12 V |
Interrupts/diagnostics/status information |
Alarms |
Alarms | Yes |
Diagnostic alarm | Yes |
Diagnoses |
Diagnostic functions | Yes |
Monitoring the supply voltage to the electronics | Yes |
Wire break | Yes |
Short circuit | Yes |
Diagnostics indication LED |
For status of the outputs | Yes |
for maintenance | Yes |
Climatic and mechanical conditions for storage and transport |
Climatic conditions for storage and transport |
Free fall |
Drop height, max. (in packaging) | 0.3 m; five times, in dispatch package |
Temperature |
Permissible temperature range | -40 °C to +70 °C |
Air pressure acc. to IEC 60068-2-13 |
Permissible air pressure | 1080 to 660 hPa |
Mechanical and climatic conditions during operation |
Climatic conditions in operation |
Temperature |
Permissible temperature range | 0 °C to 55 °C horizontal installation 0 °C to 45 °C vertical installation |
Air pressure acc. to IEC 60068-2-13 |
Permissible air pressure | 1080 to 795 hPa |
Pollutant concentrations |
SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
Degree and class of protection |
IP20 | Yes |
Standards, approvals, certificates |
CE mark | Yes |
C-TICK | Yes |
FM approval | Yes |
Connection method |
required front connector | Yes |
Mechanics/material |
Type of housing (front) | |
Plastic | Yes |
Dimensions |
Width | 45 mm |
Height | 100 mm |
Depth | 75 mm |
Weight |
Weight, approx. | 180 g |