SIPLUS S7 MEC EC31-RTX FOR MEDIAL STRESS WITH CONFORMAL COATING (LEVEL 1 BASED ON 6ES7677-1DD00-0BB0 |
General information |
Hardware product version | 04 |
Firmware version | V1.3 |
PC configuration |
Computer platform | SIMATIC S7 modular embedded controller |
Processor selection | Intel Core Duo 1.2 GHz |
Main memory | 1 GB RAM |
Flash Disk | 2 GB |
Operating systems | Windows XP embedded SP2 FP2007 |
Installed software |
Control | SIMATIC WinAC RTX 2009 |
Communication | Yes |
Supply voltage |
Rated value, 24 V DC | Yes |
permissible range, lower limit (DC) | 20.4 V |
permissible range, upper limit (DC) | 28.8 V |
Mains buffering |
Mains/voltage failure stored energy time | 5 ms |
Input current |
Rated value at 24 V DC | 800 mA; without backplane bus and USB power supply |
Power losses |
Power loss, typ. | 34 W |
Memory |
Memory type | 512 KB non-volatile memory for retentive data |
CPU processing times |
for bit operations, min. | 0.0040 µs; typ. |
for fixed point arithmetic, min. | 0.0030 µs; typ. |
for floating point arithmetic, min. | 0.0040 µs; typ. |
CPU-blocks |
DB |
Number, max. | Max. code size and max. data size: 4 MB each |
Size, max. | 64 Kibyte |
FB |
Number, max. | Max. code size and max. data size: 4 MB each |
Size, max. | 64 Kibyte |
FC |
Number, max. | Max. code size and max. data size: 4 MB each |
Size, max. | 64 Kibyte |
OB |
Number, max. | Max. code size and max. data size: 4 MB each |
Size, max. | 64 Kibyte |
Number of free cycle OBs | 1; OB 1 |
Number of time alarm OBs | 1; OB 10 |
Number of delay alarm OBs | 1; OB 20 |
Number of time interrupt OBs | 9; OB 30-38 |
Number of process alarm OBs | 1; OB 40 |
Number of startup OBs | 2; OB 100, 102 |
Number of asynchronous error OBs | 7; OB 80, 82-85, 86, 88 |
Number of synchronous error OBs | 2; OB 121, 122 |
Nesting depth |
per priority class | 24 |
additional within an error OB | 24 |
Counters, timers and their retentivity |
S7 counter |
Number | 2,048 |
Retentivity |
adjustable | Yes |
lower limit | 0 |
upper limit | 2,047 |
preset | 8 |
Counting range |
adjustable | Yes |
lower limit | 0 |
upper limit | 999 |
IEC counter |
present | Yes |
Type | SFB |
S7 times |
Number | 2,048 |
Retentivity |
adjustable | Yes |
lower limit | 0 |
upper limit | 2,047 |
Time range |
lower limit | 10 ms |
upper limit | 9,990 s |
IEC timer |
present | Yes |
Type | SFB |
Data areas and their retentivity |
retentive data area, total | 512 KB |
Flag |
Number, max. | 16 Kibyte |
of which retentive without battery | MB 0 to MB 16383 |
Retentivity preset | MB 0 to MB 15 |
Number of clock memories | 8 |
Data blocks |
Number, max. | Max. code size and max. data size: 4 MB each |
Size, max. | 64 Kibyte |
Address area |
I/O address area |
Inputs | 16 Kibyte |
Outputs | 16 Kibyte |
of which, distributed |
Inputs | 8 Kibyte |
Outputs | 8 Kibyte |
Process image |
Inputs, adjustable | 16 Kibyte |
Outputs, adjustable | 16 Kibyte |
Inputs, default | 512 byte |
Outputs, default | 512 byte |
Subprocess images |
Number of subprocess images, max. | 15 |
Digital channels |
Inputs | 128,000 |
Outputs | 128,000 |
Analog channels |
Inputs | 8,000 |
Outputs | 8,000 |
Time of day |
Clock |
Hardware clock (real-time clock) | Yes; Resolution: 1 s |
Clock synchronization |
supported | Yes |
to PC-CP, slave | Yes |
on Ethernet via NTP | Yes |
1st interface |
Type of interface | PROFINET |
Physics | 2x RJ45 |
Automatic detection of transmission speed | Yes |
Autonegotiation | Yes |
Autocrossing | Yes |
Number of connection resources | 32 |
Functionality |
MPI | No |
DP master | No |
DP slave | No |
PROFINET IO Device | No |
PROFINET IO Controller | Yes |
PROFINET CBA | Yes |
Open IE communication | Yes |
Point-to-point connection | No |
PROFINET IO Controller |
Services |
PG/OP communication | Yes |
S7 routing | Yes |
S7 communication | Yes |
Isochronous mode | No |
Number of connectable IO devices, max. | 256 |
Number of IO devices with IRT and the option "high flexibility" | 64 |
IRT, supported | Yes |
Prioritized startup supported | Yes |
Number of IO Devices, max. | 32 |
Activation/deactivation of IO Devices | Yes |
Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
IO Devices changing during operation (partner ports), supported | Yes |
Max. number of IO devices per tool | 8 |
Send cycles | Adjustable: 250 µs, 500 µs and 1 ms |
Updating times | 250 µs - 128 ms (with signal cycle 250 µs); 500 µs - 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms) |
Address area |
Inputs, max. | 16 Kibyte |
Outputs, max. | 16 Kibyte |
User data per address area, max. | 2 Kibyte |
User data consistency, max. | 256 byte |
PROFINET CBA |
acyclic transmission | Yes |
Cyclic transmission | Yes |
Open IE communication |
Open IE communication, supported | Yes |
Number of connections, max. | 32 |
Local port numbers used at the system end | 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
PROFINET functions |
Detection of accessible nodes, supported | Yes; DCP |
Assignment of the IP address, supported | Yes; DCP |
Assignment of the device name, supported | Yes; DCP |
Topology recognition, supported | Yes; LLDP, LLDP MIB, SNMP |
Extended network diagnostics with Standard MIB II, supported | Yes; Standard MIB II, SNMP |
2nd interface |
Type of interface | Integrated Ethernet interface |
Physics | Ethernet RJ45 |
Automatic detection of transmission speed | Yes |
Autonegotiation | Yes |
Autocrossing | No |
Number of connection resources | 32 |
Functionality |
PROFINET IO Controller | No |
PROFINET IO Device | No |
PROFINET CBA | No |
Communication functions |
PG/OP communication | Yes |
Global data communication |
supported | No |
S7 basic communication |
supported | No |
S7 communication |
supported | Yes |
as server | Yes |
as client | Yes |
Open IE communication |
TCP/IP | Yes; Via integrated PROFINET interface (X1) and loadable FBs |
Number of connections, max. | 32 |
Data length, max. | 8,192 byte |
ISO-on-TCP (RFC1006) | No |
UDP | Yes; Via integrated PROFINET interface (X1) and loadable FBs |
Number of connections, max. | 32 |
Data length, max. | 1,472 byte |
Number of connections |
overall | 64 |
usable for PG communication | |
reserved for PG communication | 1 |
usable for OP communication | |
reserved for OP communication | 1 |
S7 message functions |
Number of login stations for message functions, max. | 62; The alarm functions cannot currently be used for central bus modules |
Process diagnostic messages | Yes; Alarm_S |
Test commissioning functions |
Status/control |
Status/control variable | Yes |
Forcing |
Forcing | No |
Diagnostic buffer |
present | Yes |
EMC |
Emission of radio interference acc. to EN 55 011 |
Limit class A, for use in industrial areas | Yes |
Ambient conditions |
Operating temperature |
Min. | 0 °C |
max. | 50 °C |
Storage/transport temperature |
Min. | -40 °C |
max. | 70 °C |
Vibrations |
Operation, checked according to IEC 60068-2-6 | Yes |
Transport tested checked to IEC 60068-2-6 | Yes |
Shock test |
checked according to IEC 60068-2-27 | Yes |
checked according to IEC 60068-2-29 | Yes |
Shock testing |
checked according to IEC 60068-2-29 | Yes |
Operation, checked according to IEC 60068-2-29 | Operation, tested according to IEC 60068-2-27 |
Storage/transport, checked to IEC 60068-2-29 | Yes |
Degree and class of protection |
IP20 | Yes |
Standards, approvals, certificates |
CE mark | Yes |
CSA approval | No |
cULus | No |
C-TICK | No |
FM approval | No |
Configuration |
Configuration software |
STEP 7 | Yes |
programming |
Programming language |
LAD | Yes |
FBD | Yes |
STL | Yes |
SCL | Yes |
CFC | Yes |
GRAPH | Yes |
HiGraph® | Yes |
Dimensions |
Width | 160 mm |
Height | 125 mm |
Depth | 115 mm |
[nicht versorgt: TAK_ABV654_001_000] |
[nicht versorgt: TAK_ABV463_001_000] |
Product version |
STEP 7 | Yes; V5.4 SP4 and higher + HW update/iMap V3.0 SP1 |