SIPLUS ET200S EM 4 AI I 2WIRE -25 ... +60 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7134-4GD00-0AB0 . ELECTRONIC MODULE 4 - 20MA; 13BIT WIDTH: 15MM FOR 2-WIRE TRANSDUCER CYCLE TIME 40MS/MODUL WITH LED SF (GROUP FAULT) |
Supply voltage |
Load voltage L+ |
Rated value (DC) | 24 V; From power module |
Reverse polarity protection | Yes |
Input current |
from load voltage L+ (without load), max. | 125 mA |
from backplane bus 3.3 V DC, max. | 10 mA |
Output voltage |
Power supply to the transmitters |
present | Yes |
short-circuit proof | Yes; approx. 200 mA for module |
Power losses |
Power loss, typ. | 0.6 W |
Address area |
Address space per module |
Address space per module, max. | 8 byte |
Analog inputs |
Number of analog inputs | 4 |
Cycle time (all channels) max. | 40 ms; 33 to 40 ms |
permissible input current for current input (destruction limit), max. | 30 mA; limited electronically |
Input ranges |
Voltage | No |
Current | Yes |
Thermocouple | No |
Resistance thermometer | No |
Resistance | No |
Input ranges (rated values), currents |
4 to 20 mA | Yes; Into 25 Ohm |
Cable length |
Cable length, shielded, max. | 200 m |
Analog value creation |
Measurement principle | integrating |
Integrations and conversion time/ resolution per channel |
Resolution with overrange (bit including sign), max. | 13 bit; 4 to 20 mA: 13 bits |
Integration time, parameterizable | Yes |
Integration time, ms | 16.67/20 ms |
Interference voltage suppression for interference frequency f1 in Hz | 60 / 50 Hz |
Smoothing of measured values |
Parameterizable | Yes; in 4 stages |
Step: None | Yes; 1 x cycle time |
Step: low | Yes; 4 x cycle time |
Step: Medium | Yes; 16 x cycle time |
Step: High | Yes; 32 x cycle time |
Encoder |
Connection of signal encoders |
Burden of 2-wire transmitter, max. | 750 Ω |
Errors/accuracies |
Linearity error (relative to input area) | +/- 0,01 % |
Temperature error (relative to input area) | +/- 0,003 %/K |
Crosstalk between the inputs, min. | -50 dB |
Repeat accuracy in settled status at 25 °C (relative to input area) | +/- 0,05 % |
Operational limit in overall temperature range |
Current, relative to input area | +/- 0,4 % |
Basic error limit (operational limit at 25 °C) |
Current, relative to input area | +/- 0,3 % |
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency |
Series mode interference (peak value of interference < rated value of input range), min. | 70 dB |
Isochronous mode |
Isochronous mode | No |
Interrupts/diagnostics/status information |
Diagnoses |
Diagnostic functions | Yes; Can be read out |
Wire break | Yes; Measuring range 1 to 5 V only |
Group error | Yes |
Overflow/underflow | Yes |
Diagnostics indication LED |
Group error SF (red) | Yes |
Parameter |
Remark | 7 bytes |
Diagnosis: wire break | 1 |
Measurement type/range | 1 |
Group diagnostics | 1 |
Overflow/underflow | 1 |
Galvanic isolation |
Galvanic isolation analog inputs |
between the channels | No |
between the channels and the backplane bus | Yes |
between the channels and the load voltage L+ | No |
Isolation |
Isolation checked with | 500 V DC |
Ambient conditions |
Extended ambient conditions |
Relative to ambient temperature-atmospheric pressure-installation altitude | Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Relative humidity |
with condensation / maximum | 100 % |
Resistance |
to biologically active substances / conformity with EN 60721-3-3 | Yes; , Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation in corrosive atmospheres! |
to chemically active substances / conformity with EN 60721-3-3 | Yes; , Class 3C4 incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
to mechanically active substances / conformity with EN 60721-3-3 | Yes; , Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Mechanical and climatic conditions during operation |
Climatic conditions in operation |
Temperature |
Min. | -25 °C; = Tmin |
max. | 60 °C; = Tmax |
Standards, approvals, certificates |
CE mark | Yes |
Dimensions |
Width | 15 mm |
Height | 81 mm |
Depth | 52 mm |
Weight |
Weight, approx. | 40 g |
Status | Sep 14, 2011 |