Your cart is empty

3RP1505-1BW30 TIME RELAY, MULTI-FUNCTION

Part No.:
3RP1505-1BW30
Manufacturer:
SIEMENS
Weight:
0.35kg
Product Range:
Motors and Drives
3RP1505-1BW30

Product Information

TIME RELAY, MULTI-FUNCTION 2 CHANGEOVER, 16 FUNCTIONS, 15 TIME SETTING RANGES AC/DC 24... 240 V, WITH LED, SCREW CONNECTION
General technical details:
Product brand nameSIRIUS
product designationtiming relay
Protection class IP / on the frontIP40
Protection class IP / of the terminalIP20
Built in orientationany
Supply voltage frequency
  • 1 / for auxiliary and control current circuit
  • initial rated value
Hz50
  • final rated value
Hz60
Product function
  • star-delta circuit
Yes
  • with auxiliary voltage / pulse-shaping
Yes
  • at the relay outputs / changeover delayed/without delay
Yes
Product component / semi-conductor outputNo
Product extension / optional / remote controlNo
Product extension / strictly required / remote controlNo
Installation altitude / at a height over sea level / maximumm2,000
Ambient temperature
  • during storage
°C-40…85
  • during operating
°C-25…60
  • during transport
°C-40…85
Relative humidity
  • during operating phase
%15…70
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-42 kV network connection / 1 kV control connection
Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-52 kV
Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-51 kV
Electrostatic discharge / according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling / according to IEC 61000-4-310 V/m
Resistance against vibration10 ... 55 Hz / 0.35 mm
Impulse voltage resistance / rated valueV4,000
Insulation voltage / rated valueV300
Active power loss / total / typicalW2
Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750K
Item designation / according to DIN EN 61346-2K
Category / according to EN 954-1none
Switching Function:
Switching function
  • slow-operating
Yes
  • making pulse contact
No
  • firmly clocked beginning with pulse
No
  • firmly clocked beginning with pause
Yes
  • relapse delayed
Yes
  • variably clocked start with impulse
No
  • impuls variably clocked start with pause
No
  • with auxiliary voltage
  • in an additive way slow-operating
Yes
  • temporary line fault
Yes
  • relapse delayed
Yes
  • without auxiliary voltage / relapse delayed
No
  • slow-operating/instantaneous contact
Yes
  • with auxiliary voltage
  • relapse delayed/instantaneous contact
Yes
  • slow-operating/relapse delayed/instantaneous contact
Yes
  • firmly clocked beginning with pause/instantaneous contact
Yes
  • making pulse contact/instantaneous contact
Yes
  • with auxiliary voltage
  • temporary line fault/instantaneous contact
Yes
  • pulse modelling/instantaneous contact
Yes
  • slow-operating/instantaneous contact
Yes
General details:
Type of voltage / of the controlled supply voltageAC/DC
Control supply voltage frequency
  • 1
Hz50…60
Control supply voltage
  • 1
  • at 50 Hz
  • for AC
V24…240
  • at 60 Hz
  • for AC
V24…240
  • for DC
V24…240
Working range factor supply voltage rated value
  • at 50 Hz
  • for AC
0.8…1.1
  • at 60 Hz
  • for AC
0.8…1.1
  • for DC
0.7…1.1
Auxiliary circuit:
Operating current / of auxiliary contacts
  • as normally closed contact / for AC-15
  • at 24 V
A3
  • at 250 V
A3
  • as normally open contact / for AC-15
  • at 24 V
A3
  • at 250 V
A3
  • at AC-15
  • maximum
A3
  • at DC-13
  • at 24 V
A1
  • at 125 V
A0.2
  • at 250 V
A0.1
Number of NC contacts / delayed switching0
Number of NC contacts / non-delayed0
Number of NO contacts / delayed switching0
Number of NO contacts / non-delayed0
Number of change-over switches / delayed switching2
Number of change-over switches / non-delayed0
Short-circuit:
Design of the fuse link / for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 4 A
Type of mountingscrew and snap-on mounting onto 35 mm standard mounting rail
Installation/mounting/dimensions:
Widthmm22.5
Heightmm102
Depthmm91
Distance, to be maintained, to the ranks assembly
  • upwards
mm0
  • forwards
mm0
  • sidewards
mm0
  • backwards
mm0
  • downwards
mm0
Distance, to be maintained, to earthed part
  • backwards
mm0
  • sidewards
mm0
  • upwards
mm0
  • forwards
mm0
  • downwards
mm0
Distance, to be maintained, conductive elements
  • downwards
mm0
  • backwards
mm0
  • sidewards
mm0
  • forwards
mm0
  • upwards
mm0
Connections:
Design of the snap-on socket basenone
Design of the electrical connection
  • jumper socket
No
  • for auxiliary and control current circuit
screw-type terminals
Type of the connectable conductor cross-section / for auxiliary contacts / solid0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²)
Conductor cross section that can be connected / for auxiliary contacts / solid
  • minimum
mm²0.5
  • maximum
mm²4
Type of the connectable conductor cross-section / for auxiliary contacts / finely stranded / with conductor end processing0.5 ... 2.5 mm², 2x (0.5 ... 1.5 mm²)
Conductor cross-section that can be connected / for auxiliary contact / stranded wire / with conductor end processing
  • minimum
mm²0.5
  • maximum
mm²2.5
Type of the connectable conductor cross-section / for AWG conductors / for auxiliary contacts2x (20 ... 14)
AWG number / as coded connectable conductor cross-section / for auxiliary contact
  • minimum
20
  • maximum
14
Verification of suitabilityCE / UL / CSA

3 Units in Stock


Call for Availability
Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange

Ask A Question

Additional Images