SITOP PSU100M 20A STABILIZED POWER SUPPLY INPUT: 120-230 V AC 110-220 V DC OUTPUT: 24 V/20 A DC |
Technical specifications | |
Product | SITOP PSU100M |
Power supply, type | 24 V/20 A |
Input | |
Input | 1-phase and 2-phase AC or DC |
Supply voltage / at DC | 110 V…300 V |
Rated voltage value Vin rated | 120 V…230 V |
Voltage range | 85 V…275 V |
| Derating of temperature down to 50 °C necessary at Vin < 100 V AC or DC |
Input voltage / at DC | 88 V…350 V |
Wide-range input | Yes |
Overvoltage resistance | Implemented internally with varistors |
Mains buffering at Iout rated, min. | 20 ms |
Mains buffering | at Vin = 230 V |
Rated line frequency | 50 Hz/60 Hz |
Rated line range | 45 Hz...65 Hz |
Input current / at nominal level of the input voltage 120 V | 4.6 A |
Input current / at nominal level of the input voltage 230 V | 2.5 A |
Switch-on current limiting (+25 °C), max. | 20 A |
I²t, max. | 5 A²·s |
Built-in incoming fuse | Yes |
Protection in the mains power input (IEC 898) | Recommended miniature circuit breaker at 1-phase operation: 10 A , characteristic C; required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker (8 or 4 A) acc. to UL 489: 3RV2711-1HD10 (120 V) or 3RV2711-1ED10 (230 V) |
Output | |
Output | controlled, isolated DC voltage |
Rated voltage Vout DC | 24 V |
Total tolerance, static ± | 3 % |
Static mains compensation, approx. | 0.1 % |
Static load balancing, approx. | 0.3 % |
Residual ripple peak-peak, max. | 100 mV |
Residual ripple peak-peak, typ. | 80 mV |
Spikes peak-peak, max. (bandwidth: 20 MHz) | 200 mV |
Spikes peak-peak, typ. (bandwidth: 20 MHz) | 100 mV |
Adjustment range | 24 V…28.8 V |
Product feature / output voltage adjustable | Yes |
Output voltage setting | via potentiometer |
Status display | Green LED for 24 V OK |
Signaling | Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK" |
On/off behavior | No overshoot of Vout (soft start) |
Startup delay, max. | 0.25 s |
Voltage rise, typ. | 50 ms |
Rated current value Iout rated | 20 A |
Current range | 0 A…20 A |
| > 60 °C Derating |
delivered active power / typ. | 480 W |
constant overload current / at short-circuit during run-up / typical | 30 A |
short-term overload current / at short-circuit during operation / typical | 60 A |
Duration of overloading ability for excess current / on short-circuiting during the operational phase | 25 ms |
Parallel switching for enhanced performance | Yes |
| switchable characteristic |
Numbers of parallel switchable units for enhanced performance | 2 |
Efficiency | |
Efficiency at Vout rated, Iout rated, approx. | 93 % |
Power loss at Vout rated, Iout rated, approx. | 42 W |
Closed-loop control | |
Dynamic mains compensation (Vin rated ±15 %), max. | 0.5 % |
Dynamic load smoothing (Iout: 50/100/50 %), Uout ± typ. | 1 % |
Load step setting time 50 to 100%, typ. | 1 ms |
Load step setting time 100 to 50%, typ. | 1 ms |
Setting time / maximum | 5 ms |
Protection and monitoring | |
Output overvoltage protection | < 33 V |
Current limitation, typ. | 21.5 A |
Characteristic feature of the output / short-circuit protected | Yes |
Short-circuit protection | Alternatively, constant current characteristic approx. 23 A or latching shutdown |
Enduring short circuit current / Effective level / typical | 23 A |
| overload capability 150 % Iout rated up to 5 s/min |
Overload/short-circuit indicator | LED yellow for "overload", LED red for "latching shutdown" |
Safety | |
Primary/secondary isolation | Yes |
Potential separation | Safety extra low output voltage Vout according to EN 60950-1 and EN 50178 |
Protection class | Class I |
stray current / maximum | 3.5 mA |
stray current / typical | 1 mA |
CE mark | Yes |
UL/CSA approval | Yes |
UL/cUL (CSA) approval | cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259 |
Explosion protection | in preparation |
FM approval | - |
CB approval | No |
Marine approval | GL and ABS in process |
Degree of protection (EN 60529) | IP20 |
EMC | |
Emitted interference | EN 55022 Class B |
Supply harmonics limitation | EN 61000-3-2 |
Noise immunity | EN 61000-6-2 |
Operating data | |
Ambient temperature / in operation | -25 °C…70 °C |
| with natural convection |
Ambient temparature / on transport | -40 °C…85 °C |
Ambient temparature / in storage | -40 °C…85 °C |
Humidity class according to EN 60721 | Climate class 3K3, no condensation |
Mechanics | |
Connection technology | screw-type terminals |
Connections / Supply input | L, N, PE: 1 screw terminal each for 0.2 ... 4 mm² single-core/finely stranded |
Connections / Output | +, -: 2 screw terminals each for 0.2 ... 4 mm² |
Connections / Auxiliary | Alarm signals: 2 screw terminals for 0.14 ... 1.5 mm² |
Width / of the housing | 90 mm |
Height / of the housing | 125 mm |
Depth / of the housing | 125 mm |
Installation width | 90 mm |
Mounting height | 225 mm |
Weight, approx. | 1.2 kg |
Product feature / of the housing / housing for side-by-side mounting | Yes |
Type of mounting / wall mounting | No |
Type of fixing / cap rail mounting | Yes |
Type of mounting / S7-300 rail mounting | No |
Installation | Snaps onto DIN rail EN 60715 35x7.5/15 |
Electrical accessories | Buffer module |
Mechanical accessories | Device identification label 20 mm × 7 mm, pastel-turpuoise 3RT1900-1SB20 |
Last change: | Sep 21, 2011 |