Your cart is empty

3RT1016-1AF02 CONTACTOR, AC-3 4 KW/400 V,

Part No.:
3RT1016-1AF02
Manufacturer:
SIEMENS
Weight:
0.35kg
Product Range:
Motors and Drives
3RT1016-1AF02

Product Information

CONTACTOR, AC-3 4 KW/400 V, 1 NC, AC 110 V, 50/60 HZ, 3-POLE, SIZE S00, SCREW CONNECTION
General details:
Product brand nameSIRIUS
product designationpower contactor
Size of the contactorS00
Protection class IP / on the frontIP20
Degree of pollution3
Installation altitude / at a height over sea level / maximumm2,000
Ambient temperature / during operating°C-25…60
Active power loss / per conductor / typicalW0.7
Item designation
  • according to DIN EN 61346-2
Q
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
K
Mechanical operating cycles as operating time
  • of the contactor / typical
30,000,000
  • of the contactor with added auxiliary switch block / typical
10,000,000
  • of the contactor with added electronics-compatible auxiliary switch block / typical
5,000,000
Main circuit:
Number of poles / for main current circuit3
Number of NC contacts / for main contacts0
Number of NO contacts / for main contacts3
Operating current / at AC-1 / at 400 V / at 40 °C ambient temperature / rated valueA22
Operating current / at AC-1 / at 400 V / at 60 °C ambient temperature / rated valueA20
Operating current
  • at AC-3 / at 400 V / rated value
A9
  • with 1 current path
  • at DC-1
  • at 24 V / rated value
A20
  • at 110 V / rated value
A2.1
  • at DC-3 / at DC-5
  • at 24 V / rated value
A20
  • at 110 V / rated value
A0.15
  • with 2 current paths in series
  • at DC-1
  • at 24 V / rated value
A20
  • at 110 V / rated value
A12
  • at DC-3 / at DC-5
  • at 24 V / rated value
A20
  • at 110 V / rated value
A0.35
  • with 3 current paths in series
  • at DC-1
  • at 24 V / rated value
A20
  • at 110 V / rated value
A20
  • at DC-3 / at DC-5
  • at 24 V / rated value
A20
  • at 110 V / rated value
A20
Service power
  • at AC-1 / at 400 V / rated value
kW13
  • at AC-2 / at 400 V / rated value
kW4
  • at AC-3
  • at 400 V / rated value
kW4
  • at 500 V / rated value
kW4.5
  • at 690 V / rated value
kW5.5
Control circuit:
Design of activationconventional
Type of voltage / of the controlled supply voltageAC
Control supply voltage frequency
  • 1 / rated value
Hz50
  • 2 / rated value
Hz60
Control supply voltage / 1
  • at 50 Hz / for AC
  • rated value
V110
  • at 60 Hz / for AC
  • rated value
V110
Auxiliary circuit:
Contact reliability / of the auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)
Number of NC contacts / for auxiliary contacts
  • instantaneous switching
1
  • lagging switching
0
Number of NO contacts / for auxiliary contacts
  • instantaneous switching
0
  • leading switching
0
Operating current / of the auxiliary contacts
  • at AC-12 / maximum
A10
  • at AC-15
  • at 230 V
A6
  • at 400 V
A3
  • at DC-12
  • at 60 V
A6
  • at 110 V
A3
  • at 220 V
A1
  • at DC-13
  • at 24 V
A10
  • at 60 V
A2
  • at 110 V
A1
  • at 220 V
A0.3
Short-circuit:
Design of the fuse link
  • for short-circuit protection of the auxiliary switch / required
fuse gL/gG: 10 A
  • for short-circuit protection of the main circuit
  • with type of assignment 1 / required
fuse gL/gG: 35 A
  • at type of coordination 2 / required
fuse gL/gG: 20 A
Installation/mounting/dimensions:
Type of mountingscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
series installationYes
Widthmm45
Heightmm57.5
Depthmm72
Distance, to be maintained, to earthed part / sidewardsmm6
Connection type:
Design of the electrical connection
  • for main current circuit
screw-type terminals
  • for auxiliary and control current circuit
screw-type terminals
Identification number and letter for switching elements01 E

1 Units in Stock


Call for Availability
Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange

Ask A Question