Your cart is empty

3RB2143-4EB0 OVERLOAD RELAY 25...100 A

Part No.:
3RB2143-4EB0
Manufacturer:
SIEMENS
Weight:
4kg
Product Range:
Motors and Drives
3RB2143-4EB0

Product Information

OVERLOAD RELAY 25...100 A FOR MOTOR PROTECTION SIZE S3, CLASS 5...30 FOR MOUNTING ONTO CONT. MAIN CIRCUIT: SCREW CONNECTION AUX. CIRCUIT: SCREW CONNECTION MANUAL-AUTOMATIC-RESET INT. EARTH FAULT DETECTION
General technical details:
Product brand nameSIRIUS
product designationsolid-state overload relay
Protection class IP / on the frontIP20
Insulation voltage / with degree of pollution 3 / rated valueV1,000
Adjustable response current
  • of the current-dependent overload release
A25…100
EMC emitted interferencedegree of severity B according to EN 55011 (CISPR 11) and EN 55022 (CISPR 22)
Electrostatic discharge / according to IEC 61000-4-26 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling / according to IEC 61000-4-310 V/m
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-42 kV (power ports), 1 kV (signal ports) corresponds to degree of severity 3
Conductor-bound parasitic coupling conductor-earth SURGE2 kV (line to earth) corresponds to degree of severity 3
Conductor-bound parasitic coupling conductor-conductor SURGE1 kV (line to line) corresponds to degree of severity 3
Resistance against shock15g / 11 ms
Impulse voltage resistance / rated valuekV8
Active power loss / total / typicalW0.05
type of protectionPTB 06 ATEX 3001 Ex II (2) GD
Type of assignement2
Trip classCLASS 5, 10, 20 and 30 adjustable
Item designation
  • according to DIN EN 61346-2
F
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
F
Control circuit:
Design of the electrical connection / for auxiliary and control current circuitscrew-type terminals
Main circuit:
Number of poles / for main current circuit3
Operating voltage / at AC-3 / rated value / maximumV1,000
Operating current / of the fuse link
  • rated value
A315
Service power / for three-phase servomotors
  • rated value
kW11…45
Design of the electrical connection / for main current circuitscrew-type terminals
Service power / for three-phase servomotors / at 400 V / at 50 Hz
  • for AC three-phase
kW11…45
Auxiliary circuit:
Contact reliability / of the auxiliary contactsacceptability for PLC control (17 V, 5 mA)
Operating current / of the auxiliary contacts
  • at AC-15
  • at 24 V
A4
  • at 110 V
A4
  • at 120 V
A4
  • at 125 V
A4
  • at 230 V
A3
  • at DC-13
  • at 24 V
A2
  • at 60 V
A0.55
  • at 110 V
A0.3
  • at 125 V
A0.3
  • at 220 V
A0.11
Number of NC contacts1
Number of NO contacts1
Number of change-over switches0
Short-circuit:
Design of the fuse link / for short-circuit protection of the auxiliary switch / requiredfuse gL/gG: 6 A
Mechanical design:
Built in orientationany
Type of mountingdirect mounting
Size of the contactor / can be combined / company-specificS3
Size of overload relayS3
Widthmm70
Heightmm106
Depthmm124
Distance, to be maintained, to the ranks assembly
  • upwards
mm0
  • forwards
mm0
  • sidewards
mm0
  • backwards
mm0
  • downwards
mm0
Distance, to be maintained, to earthed part
  • upwards
mm0
  • forwards
mm0
  • sidewards
mm6
  • backwards
mm0
  • downwards
mm0
Distance, to be maintained, conductive elements
  • upwards
mm0
  • forwards
mm0
  • sidewards
mm6
  • backwards
mm0
  • downwards
mm0
Ambient conditions:
Ambient temperature
  • during operating
°C-25…60
Ambient temperature
  • during storage
°C-40…80
Ambient temperature
  • during transport
°C-40…80
Relative humidity / during operating phase / maximum%100
Installation altitude / at a height over sea level / maximumm2,000
Protection class IPIP20
Connections:
Product function / removable terminal for auxiliary and control circuitYes
Type of the connectable conductor cross-section
  • for main contacts
  • solid
2x (2.5 ... 16 mm²)
  • finely stranded
  • with conductor end processing
2x (2.5 ... 35 mm²), 2.5 ... 50 mm²
  • stranded
2x (10 ... 50 mm²), 10 ... 70 mm²
  • for AWG conductors / for main contacts
2x (10 ... 1/0), 1x (10 ... 2/0)
Type of the connectable conductor cross-section
  • for auxiliary contacts
  • solid
0.5 ... 4 mm², 2x (0.5 ... 2.5 mm²)
  • finely stranded
  • with conductor end processing
0.5 ... 2.5 mm², 2x (0.5 ... 1.5 mm²)
  • for AWG conductors / for auxiliary contacts
2x (20 ... 14)
Verification of suitabilityCSA / UL / CCC / GL / LRS / DNV / ABS

1 Units in Stock


Call for Availability
Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange

Ask A Question