Product type designation | SCALANCE X414-3E |
| SCALANCE X414-3E, MODULAR IE SWITCH, 2 X 10/100/1000MBIT/S AND 12 X 10/100MBIT/S RJ45 PORTS, 1 X GIGAGBIT AND 2 X 100 MBIT MEDIA MODULE SLOTS, EXTENDER INTERFACE, INTEGRATED REDUNDANCY MANAGER, OFFICE FEATURES (RSTP, VLAN,..) NETWORK MANAGEMENT, C-PLUG INCLUDED IN THE SCOPE OF SUPPLY |
Transmission rate | |
Transfer rate / 1 | 10 Mbit/s |
Transfer rate / 2 | 100 Mbit/s |
Transfer rate / 3 | 1000 Mbit/s |
Interfaces | |
Number of electrical/optical connections / for network components or terminal equipment / maximum | 26 |
Number of electrical connections / for operator console | 1 |
Design of electrical connection / for operator console | RS232 port |
Number of electrical connections | |
- for network components and terminal equipment
| 14 |
| 8 |
| 1 |
| 3 |
| 1 |
- for redundant power supply
| 1 |
Design of electrical connection | |
- for network components and terminal equipment
| RJ45 port (2 x 1GE, 12 x FE) |
| RJ45 port via EM495-8 |
| 4-pole terminal block |
| 4-pole terminal block |
Number of optical interfaces / for optical waveguide | |
| 4 |
| 2 |
| 8 |
Design of optical interface / for optical waveguide | |
| BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+ |
| SC ports via media modules MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+ |
| BFOC or SC ports via media modules MM491-2, MM491-2LD, MM491-2LH+, MM492-2, MM492-2LD, MM492-2LH, MM492-2LH+ |
Number of extender expansion interfaces | 1 |
design of the extender extension interface | EM495-8 or EM496-4 |
design of the removable storage / C-PLUG | Yes |
Inputs/outputs | |
Operating voltage / of signaling contacts / at DC / rated value | 24 V |
Operating current / of signaling contacts / at DC / maximum | 0.1 A |
Number of digital inputs | 2 |
Number of electrical connections / for digital input signals | 2 |
Design of electrical connection / for digital input signals | 5-pole terminal block |
Supply voltage, current consumption, power loss | |
Type of voltage / of supply voltage | DC |
Supply voltage / external | 24 V |
| 20.4 V |
| 28.8 V |
Product component / fusing at power supply input | Yes |
Consumed current / maximum | 2 A |
Active power loss | |
| 15 W |
| 48 W |
Permitted ambient conditions | |
Ambient temperature | |
| -40 °C…70 °C |
| -40 °C…80 °C |
| -40 °C…80 °C |
Relative humidity / at 25 °C / without condensation / during operating / maximum | 95 % |
Protection class IP | IP20 |
Design, dimensions and weight | |
Design | Modular |
Width | 344 mm |
Height | 145 mm |
Depth | 117 mm |
Net weight | 3.07 kg |
Type of mounting | |
| Yes |
| No |
| Yes |
Product properties, functions, components / general | |
Cascading in the case of a redundant ring / at reconfiguration time of <~0.3~s | 50 |
Cascading in cases of star structuring | Any (depending only on signal propagation time) |
Product function | |
| Yes |
| Yes |
| Yes |
| Yes |
- Configuration with STEP 7
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Protocol / is supported | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Identification & maintenance | |
- I&M0 - device-specific information
| Yes |
- I&M1 - plant identification/location name
| Yes |
Product functions / Diagnosis | |
Product function | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Product functions / VLAN | |
Product function | |
| Yes |
| Yes |
Number of VLANs / maximum | 64 |
Number of VLANs - dynamic / maximum | 64 |
Protocol / is supported / GVRP | Yes |
Product functions / DHCP | |
Product function | |
| Yes |
| Yes |
| Yes |
| Yes |
Product functions / Routing | |
Product function | |
| Yes |
| Yes |
Protocol / is supported | |
| Yes |
| Yes |
| Yes |
Product functions / Redundancy | |
Product function | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Protocol / is supported | |
| Yes |
| Yes |
| Yes |
| Yes |
| Yes |
Product functions / Security | |
Product function | |
| Yes |
| Yes |
| Yes |
- Broadcast/Multicast/Unicast Limiter
| Yes |
| Yes |
Protocol / is supported / SSH | Yes |
Product functions / Time | |
Product function / SICLOCK support | Yes |
Protocol / is supported | |
| No |
| Yes |
Standards, specifications, approvals | |
Standard | |
| FM3611: Class 1, Division 2, Group A, B, C, D / T4 A, Class 1, Zone 2, Group IIC, T4 |
| EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT4, KEMA 07 ATEX 0145 X |
- for safety / of CSA and UL
| UL 60950-1, CSA C22.2 No. 60950-1-03 |
- for hazardous area / of CSA and UL
| UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T4, Class 1 / Zone 2 / Group IIC / T4 |
| EN 61000-6-4:2001 (Class A) |
- for interference immunity
| EN 61000-6-2:2001 |
Verification of suitability | EN 61000-6-2:2001, EN 61000-6-4:2001 |
| Yes |
| Yes |
Marine classification association | |
- American Bureau of Shipping Europe Ltd. (ABS)
| Yes |
| Yes |
| Yes |
| Yes |
- Lloyds Register of Shipping (LRS)
| Yes |
| Yes |
Last change: | Oct 24, 2011 |