Your cart is empty

6GK5212-2BB00-2AA3 SCALANCE X212-2

Manufacturer:
Weight:
1.2kg

Product Information

Product type designationSCALANCE X212-2
SCALANCE X212-2, MANAGED IE SWITCH, 12 X 10/100MBIT/S RJ45 PORTS, 2 X 100MBIT/S MULTIMODE BFOC, LED-DIAGNOSTICS, FAULT SIGNAL. CONTACT WITH SET BUTTON, REDUNDANT POWER SUPPLY PROFINET-IO DEVICE, NETWORK- MANAGEMENT, INTEGRATED REDUNDANCY MANAGER, INCL. ELECTRONIC MANUAL ON CD, C-PLUG OPTIONAL
Transmission rate
Transfer rate / 110 Mbit/s
Transfer rate / 2100 Mbit/s
Interfaces
Number of electrical/optical connections
  • for network components or terminal equipment / maximum
14
Number of electrical connections
  • for network components and terminal equipment
12
  • for alarm contact
1
  • for power supply
1
  • for redundant power supply
1
Design of electrical connection
  • for network components and terminal equipment
RJ45 port
  • for signaling contact
2-pole terminal block
  • for power supply
4-pole terminal block
Number of optical interfaces / for optical waveguide / at 100 Mbit/s2
Design of optical interface / for optical waveguide / at 100 Mbit/sBFOC sockets (multimode up to 5 km)
Connectable optical power relative to 1 mW
  • of the transmitter output
-19 dB…-14 dB
Optical sensitivity relative to 1 mW / of the receiver input / minimum-34 dB
Attenuation / of fiber-optic cable transmission link / minimum necessary0 dB
Range / at the optical interface / depending on the optical fiber used0 km…5 km
design of the removable storage / C-PLUGYes
Inputs/outputs
Operating voltage / of signaling contacts / at DC / rated value24 V
Operating current / of signaling contacts / at DC / maximum0.1 A
Supply voltage, current consumption, power loss
Type of voltage / of supply voltageDC
Supply voltage / external24 V
  • minimum
18 V
  • maximum
32 V
Product component / fusing at power supply inputYes
Consumed current / maximum0.33 A
Active power loss / at 24 V / for DC7.92 W
Permitted ambient conditions
Ambient temperature
  • during operating
-40 °C…60 °C
  • during storage
-40 °C…70 °C
  • during transport
-40 °C…70 °C
Relative humidity / at 25 °C / without condensation / during operating / maximum95 %
Protection class IPIP30
Design, dimensions and weight
DesignCompact
Width120 mm
Height125 mm
Depth124 mm
Net weight1.2 kg
Type of mounting
  • 35 mm DIN rail mounting
Yes
  • wall mounting
Yes
  • S7-300 rail mounting
Yes
Product properties, functions, components / general
Cascading in the case of a redundant ring / at reconfiguration time of <~0.3~s50
Cascading in cases of star structuringAny (depending only on signal propagation time)
Product function
  • CLI
Yes
  • web-based management
Yes
  • MIB support
Yes
  • TRAPs via email
Yes
  • Configuration with STEP 7
Yes
  • SMTP server
Yes
  • Port mirroring
Yes
  • for IRT / PROFINET IO switch
No
  • PROFINET IO diagnosis
Yes
  • switch-managed
Yes
Protocol / is supported
  • Telnet
Yes
  • HTTP
Yes
  • HTTPS
Yes
  • TFTP
Yes
  • FTP
Yes
  • BOOTP
No
  • SNMP v1
Yes
  • SNMP v2
Yes
  • SNMP v3
Yes
  • DCP
Yes
  • LLDP
Yes
Identification & maintenance
  • I&M0 - device-specific information
Yes
  • I&M1 - plant identification/location name
Yes
Product functions / Diagnosis
Product function
  • Port diagnostics
Yes
  • Statistics Packet Size
Yes
  • Statistics packet type
Yes
  • Error statistics
Yes
Product functions / DHCP
Product function / DHCP clientYes
Product functions / Redundancy
Product function
  • Ring redundancy
Yes
  • Redundancy manager
Yes
  • Standby redundancy
No
  • HSR redundancy protocol
Yes
  • MRP redundancy protocol
Yes
  • Passive listening
Yes
Product functions / Security
Protocol / is supported / SSHYes
Product functions / Time
Product function / SICLOCK supportYes
Protocol / is supported
  • NTP
No
  • SNTP
Yes
Standards, specifications, approvals
Standard
  • for EMC / from FM
FM3611: Class 1, Division 2, Group A, B, C, D / T4, CL.1, Zone 2, GP. IIC, T4
  • for hazardous zone
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X
  • for safety / of CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1
  • for hazardous area / of CSA and UL
ANSI / ISA 12.12.01, CSA C22.2 No. 213-M1987, CL. 1 / Div. 2 / GP. A, B, C, D T4, CL. 1 / Zone 2 / GP. IIC, T4
  • for emitted interference
EN 61000-6-4:2001 (Class A)
  • for interference immunity
EN 61000-6-2:2001
Verification of suitabilityEN 61000-6-2:2001, EN 61000-6-4:2001
  • CE mark
Yes
  • C-Tick
Yes
  • Railway application in accordance with EN 50155
No
  • Railway application in accordance with EN 50124-1
No
Marine classification association
  • American Bureau of Shipping Europe Ltd. (ABS)
Yes
  • Bureau Veritas (BV)
Yes
  • Det Norske Veritas (DNV)
Yes
  • Germanische Lloyd (GL)
Yes
  • Lloyds Register of Shipping (LRS)
Yes
  • Nippon Kaiji Kyokai (NK)
Yes
  • Polski Rejestr Statkow (PRS)
No
Last change:Oct 24, 2011

6 Units in Stock


Call for Availability

Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange

Ask A Question

Additional Images