Your cart is empty

3RK1402-3CE00-0AA2 AS-INTERFACE SLIMLINE MOD. S45,

Manufacturer:
SIEMENS
Weight:
0.25kg

Product Information

AS-INTERFACE SLIMLINE MOD. S45, DIGITAL, 4I/4OR, 2/3-WIRE, IP20 4 X 1 INPUT, 200MA, PNP, 4 X 1 OUTPUT, RELAY, 6A,UC 230V SCREW-TYPE TERMINAL CONNECT., MODULE WIDTH 45 MM
General technical data:
Design of the productSlimLine S22.5 - I/O modules for operation in the control cabinet
Design of the slave typestandard slave
Type4 inputs / 4 outputs
I/O configuration7
ID/ID2 code0/F
Protocol / will be supported / AS interface protocolYes
AS interface / total current input / maxmA270
operating voltage
  • according to AS-Interface spezification
V26.5…31.6
Addressingfront addressing socket
Design of the electrical connection / of the inputs and outputsscrew-type terminals
Item designation
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
A
  • according to DIN EN 61346-2
K
noteAn external additional supply (AUX POWER) of 20 to 30 V DC is required for the supply of the output circuits.The additional supply must comply with VDE 0106 (PELV), protection class III.
Sensor supply:
Type of voltage supply / for the sensor supplyusing AS-Interface
Input voltageV20…30
Characteristic feature of the sensor supply / short-circuit and overload resistantYes
Current carrying capacity / of the sensor supply / for all inputs
  • at ambient temperature 40 °C
mA200
Inputs:
Number of digital inputs4
type of the connection technology2 and 3-conductor technology
Input circuitPNP transistor
Type of voltage / of the input voltageDC
Inputs / switching level High / minV10
Input current / at the digital input
  • for signal <1> / minimum
mA5
  • at signal <0> / maximum
mA1.5
Inputs / sensor supply using AS-Interfaceshort-circuit and overload resistant
Outputs:
Number of digital outputs4
Output voltage / at 24 V
  • for DC
V22…24
Outputs
  • current carrying capacity / Ith
A5
Current-carrying capacity
  • of the output relay
  • at DC-13
  • at 24 V
A1
  • at 110 V
A0.2
  • at 230 V
A0.1
  • at AC-15 / at 230 V / at 50/60 Hz
A3
Design of the switching outputrelay, changeover floating
Characteristic feature of the output / short-circuit protectedNo
output / Polarity reversal protectiondoes not apply
Outputs
  • short-ciruit protection
external back-up fuse required: 6 A gL/gG
  • induction protection
does not apply
  • watchdog
built-in
Status display
  • display of I/Os
yellow LED
  • AS-Interface
green LED
  • FAULT
red LED
Assignment of data bits
  • D0
IN1/OUT1
  • D1
IN2 /OUT2
  • D2
IN3/OUT3
  • D3
IN4/OUT4
Ambient conditions:
Ambient temperature
  • during operating
°C-25…70
  • during storage
°C-40…85
Protection class IPIP20
Mechanical design:
Widthmm45
Heightmm106
Depthmm86
Type of mounting35 mm standard rail mounting or wall mounting using push-in lugs
Conductor cross-section
  • solid
1 x (0.5 - 4) mm² or 2 x (0.5 - 2.5) mm²
  • finely stranded
  • with end sleeve
1 x (0.5 - 2.5) mm² or 2 x (0.5 - 1.5) mm²
  • AWG / solid or stranded
AWG 2 x (20 - 14) mm²
AS-Interface certificateyes (or requested for in case of new units)
ApprovalsUL, CSA, shipbuilding (or requested for in case of new units)

1 Units in Stock


Call for Availability
Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support