Your cart is empty

6AG1414-4HM14-4AB0 SIPLUS S7-400 CPU414-4H

Manufacturer:
SIEMENS
Weight:
1.5kg
Product Range:
Converters

Product Information

SIPLUS S7-400 CPU414-4H FOR MEDIAL STRESS BASED ON 6ES7414-4HM14-0AB0
General information
Hardware product version1
Firmware versionV4.5
[nicht versorgt: TAK_ABW067_001_000]
associated programming packageSTEP7 V 5.3 SP2 or higher with HW update
CiR - Configuration in RUN
CiR synchronization time, basic load100 ms
CiR synchronization time, time per I/O slave25 µs
Supply voltage
24 V DCNo; Power supply via system power supply
Input current
from backplane bus 5 V DC, typ.1.4 A
from backplane bus 5 V DC, max.1.7 A
from backplane bus 24 V DC, max.150 mA; Per DP interface
from interface 5 V DC, max.90 mA; At each DP interface
Power losses
Power loss, typ.6 W
Backup battery
Battery operation
Backup current, typ.190 µA; Valid up to 40°C
Backup current, max.660 µA
Backup time, max.Dealt with in the module data manual with the secondary conditions and the factors of influence
Feeding of external backup voltage to CPU5 to 15 VDC
Feeding of external backup voltage to CPU5 to 15 VDC
Memory
Work memory
integrated2.8 Mbyte
integrated (for program)1.4 Mbyte
integrated (for data)1.4 Mbyte
expandableNo
Load memory
expandable FEPROMYes
expandable FEPROM, max.64 Mbyte
integrated RAM, max.256 Kibyte
expandable RAMYes
expandable RAM, max.64 Mbyte
Backup
presentYes
with batteryYes; all data
without batteryNo
CPU processing times
for bit operations, min.0.045 µs
for word operations, min.0.045 µs
for fixed point arithmetic, min.0.045 µs
for floating point arithmetic, min.0.135 µs
CPU-blocks
DB
Number, max.4,095; Number range: 1 to 4095
Size, max.64 Kibyte
FB
Number, max.2,048; Number range: 0 to 2047
Size, max.64 Kibyte
FC
Number, max.2,048; Number range: 0 to 2047
Size, max.64 Kibyte
OB
Size, max.64 Kibyte
Number of time alarm OBs4
Number of delay alarm OBs4
Number of time interrupt OBs4
Number of process alarm OBs4
Nesting depth
per priority class24
additional within an error OB1
Counters, timers and their retentivity
S7 counter
Number2,048
Retentivity
adjustableYes
lower limit0
upper limit2,047
presetZ 0 to Z 7
Counting range
lower limit0
upper limit999
IEC counter
presentYes
TypeSFB
S7 times
Number2,048
Retentivity
adjustableYes
lower limit0
upper limit2,047
presetNo times retentive
Time range
lower limit10 ms
upper limit9,990 s
IEC timer
presentYes
TypeSFB
Data areas and their retentivity
retentive data area, totalTotal working and load memory (with backup battery)
Flag
Number, max.8 Kibyte
Retentivity availableYes
Retentivity presetMB 0 to MB 15
Number of clock memories8; (in 1 memory byte)
Data blocks
Number, max.4,095; Number range: 1 to 4095
Size, max.64 Kibyte
Local data
adjustable, max.16 Kibyte
preset8 Kibyte
Address area
I/O address area
Inputs8 Kibyte
Outputs8 Kibyte
of which, distributed
MPI/DP interface, inputs2 Kibyte
MPI/DP interface, outputs2 Kibyte
DP interface, inputs6 Kibyte
DP interface, outputs6 Kibyte
Process image
Inputs, adjustable8 Kibyte
Outputs, adjustable8 Kibyte
Inputs, default256 byte
Outputs, default256 byte
consistent data, max.244 byte
Access to consistent data in process imageYes
Subprocess images
Number of subprocess images, max.15
Digital channels
Inputs65,536
Outputs65,536
Inputs, of which central65,536
Outputs, of which central65,536
Analog channels
Inputs4,096
Outputs4,096
Inputs, of which central4,096
Outputs, of which central4,096
Hardware configuration
Expansion devices, max.21
connectable OPs31 without message processing, 8 with message processing
MulticomputingNo
Interface modules
Number of connectable IMs (total), max.6
Number of connectable IM 460s, max.6
Number of connectable IM 463s, max.4; Single mode only
Number of DP masters
integrated2
via CP10
Mixed mode IM + CP permittedNo
Number of operable FMs and CPs (recommended)
FMSee manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
CP, point-to-pointSee manual Automation System S7-400H fault-tolerant systems. Limited by number of slots and number of connections
PROFIBUS and Ethernet CPs14; Of which max. 10 CP as DP master
Time of day
Clock
Hardware clock (real-time clock)Yes
battery-backed and synchronizableYes
Resolution1 ms
Deviation per day (buffered), max.1.7 ms; Power off
Deviation per day (unbuffered) max.8.6 ms; Power on
Operating hours counter
Number8
Number/Number range0 to 7
Range of values0 to 32767 hours
Granularity1 hour
retentiveYes
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
to DP, masterYes
to DP, slaveYes
in AS, masterYes
in AS, slaveYes
Time difference in system when synchronizing via
MPI, max.200 ms
Digital outputs
integrated channels (DO)0
Analog inputs
Integrated channels (AI)0
Interfaces
Number of parallel interfaces0
Number of 20 mA interfaces (TTY)0
Number of RS 232 interfaces0
Number of RS 422 interfaces0
Number of other hardware interfaces0
1st interface
Type of interfaceintegrated
PhysicsRS 485 / PROFIBUS + MPI
IsolatedYes
Power supply to interface (15 to 30 V DC), max.150 mA
Number of connection resourcesMPI: 32, DP: 32
Functionality
MPIYes
DP masterYes
DP slaveNo
MPI
Number of connections32
Services
PG/OP communicationYes
RoutingYes
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
Transmission rate, max.12 Mbit/s
DP master
Number of connections, max.16
Services
PG/OP communicationYes
RoutingYes
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
Equidistance mode supportNo
SYNC/FREEZENo
Activation/deactivation of DP slavesNo
Direct data exchange (slave-to-slave communication)No
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.32
Address area
Inputs, max.2 Kibyte
Outputs, max.2 Kibyte
User data per DP slave
User data per DP slave, max.244 byte
Inputs, max.244 byte
Outputs, max.244 byte
Slots, max.244
per slot, max.128 byte
2nd interface
Type of interfaceintegrated
PhysicsRS 485 / PROFIBUS + MPI
IsolatedYes
Power supply to interface (15 to 30 V DC), max.150 mA
Media redundancy
Number of connection resources16
Functionality
DP masterYes
DP slaveNo
DP master
Number of connections, max.16
Services
PG/OP communicationYes
RoutingYes
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
Equidistance mode supportNo
SYNC/FREEZENo
Activation/deactivation of DP slavesNo
Direct data exchange (slave-to-slave communication)No
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.96
Address area
Inputs, max.6 Kibyte
Outputs, max.6 Kibyte
User data per DP slave
User data per DP slave, max.244 byte
Inputs, max.244 byte
Outputs, max.244 byte
Slots, max.244
per slot, max.128 byte
3rd interface
Type of interfacePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization submodule IF 960 6ES7 960-1AA04-0XA0 or 6ES7 960-1AB04-0XA0
4th interface
Type of interfacePluggable synchronization submodule (FO)
Plug-in interface modulesSynchronization submodule IF 960 6ES7 960-1AA04-0XA0 or 6ES7 960-1AB04-0XA0
Communication functions
PG/OP communicationYes
Number of connectable OPs without message processing31
Number of connectable OPs with message processing8
Global data communication
supportedNo
S7 basic communication
supportedNo
S7 communication
supportedYes
as serverYes
as clientYes
User data per job, max.64 Kibyte
User data per job (of which consistent), max.462 byte; 1 variable
S5-compatible communication
supportedYes; (via CP max. 10 and FC AG_SEND and FC AG_RECV)
User data per job, max.8 Kibyte
User data per job (of which consistent), max.240 byte
Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.24/24
Standard communication (FMS)
supportedYes; Via CP and loadable FB
Number of connections
overall32
usable for PG communication
reserved for PG communication1
Adjustable for PG communication, max.0
usable for OP communication
reserved for OP communication1
adjustable for OP communication, max.0
usable for S7 basic communication
Reserved for S7 basic communication0
adjustable for S7 basic communication, max.0
usable for S7 communication
reserved for S7 communication0
Adjustable for S7 communication, max.0
usable for routing
Reserved for routing0
adjustable for routing, max.0
S7 message functions
Number of login stations for message functions, max.8
Symbol-related messagesNo
Number of additional values
Block related messagesYes
simultaneously active Alarm-S blocks, max.100
Alarm 8-blocksYes
Number of instances for alarm 8 and S7 communication blocks, max.1,200
preset, max.900
Process control messagesYes
Number of archives that can log on simultaneously (SFB 37 AR_SEND)16
Test commissioning functions
Status/control
Status/control variableYes
VariablesInputs/outputs, memory bits, DBs, distributed I/Os, timers, counters
Number of variables, max.70
Forcing
ForcingYes
Force, variablesInputs/outputs, bit memories, distributed I/Os
Number of variables, max.256
Status blockYes
Single stepYes
Number of breakpoints4
Diagnostic buffer
presentYes
Number of entries, max.3,200
adjustableYes
preset120
Configuration
Configuration software
STEP 7Yes
programming
Programming language
LADYes
FBDYes
STLYes
SCLYes
CFCYes
GRAPHYes
HiGraph®Yes
Command setsee instruction list
Nesting levels8
Access to consistent data in process imageYes
System functions (SFC)see instruction list
Number of simultaneously active SFCs
RD_REC8
WR_REC8
WR_PARM8
PARM_MOD1
WR_DPARM2
DPNRM_DG8
RDSYSST8
DP_TOPOL1
System function blocks (SFB)see instruction list
Number of simultaneously active SFBs
RD_REC8
WR_REC8
Know-how protection
User program protection/password protectionYes
Dimensions
Width50 mm
Height290 mm
Depth219 mm
Required slots2
Weight
Weight, approx.995 g
internTechDB
Characteristics will be deleted after 2012-12-31
Product version
STEP 7Yes; With hardware update as of STEP7 V5.3 SP2

1 Units in Stock


Call for Availability
Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange

Ask A Question