6ES7318-3FL01-0AB0 CPU319F-3 PN/DP, 2.5 MB

Manufacturer:
SIEMENS
Weight:
1.25kg
Product Range:
Automation Systems

Product Information

SIMATIC S7-300 CPU319F-3 PN/DP, CENTRAL PROCESSING UNIT WITH 2.5 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, 3. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY
General information
Hardware product version01
Firmware versionV3.2
[nicht versorgt: TAK_ABW067_001_000]
associated programming packageSTEP 7 V 5.5 or higher, Distributed Safety V 5.4 SP4
Supply voltage
24 V DCYes
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
External protection for supply cables (recommendation)2 A min.
Mains buffering
Mains/voltage failure stored energy time5 ms
Repeat rate, min.1 s
Input current
Current consumption (rated value)1250 mA
Current consumption (in no-load operation), typ.500 mA
Inrush current, typ.4 A
I2t1.2 A2·s
Power losses
Power loss, typ.14 W
Memory
Work memory
integrated2560 Kibyte
expandableNo
Size of retentive memory for retentive data blocks700 Kibyte
Load memory
pluggable (MMC)Yes
pluggable (MMC), max.8 Mbyte
Data management on MMC (after last programming), min.10 a
Backup
presentYes
without batteryYes
CPU processing times
for bit operations, min.0.0040 μs
for word operations, min.0.01 μs
for fixed point arithmetic, min.0.01 μs
for floating point arithmetic, min.0.04 μs
CPU-blocks
Number of blocks (total)4096; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.
DB
Number, max.4096; Number range: 1 to 16000
Size, max.64 Kibyte
FB
Number, max.4096; Number range: 0 to 7999
Size, max.64 Kibyte
FC
Number, max.4096; Number range: 0 to 7999
Size, max.64 Kibyte
OB
Size, max.64 Kibyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs2; OB 20, 21
Number of time interrupt OBs4; OB 32, 33, 34, 35 (OB 35: smallest settable clock pulse = 500 μs)
Number of process alarm OBs1; OB 40
Number of DPV1 alarm OBs3; OB 55, 56, 57
Number isochronous mode OBs1; OB 61
Number of startup OBs1; OB 100
Number of asynchronous error OBs6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO)
Number of synchronous error OBs2; OB 121, 122
Nesting depth
per priority class16
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number2048
Retentivity
adjustableYes
lower limit0
upper limit2047
presetZ 0 to Z 7
Counting range
adjustableYes
lower limit0
upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number2048
Retentivity
adjustableYes
lower limit0
upper limit2047
presetNo retentivity
Time range
lower limit10 ms
upper limit9990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area, totalAll, max. 700 KB
Flag
Number, max.8192 byte
Retentivity availableYes; MB 0 to MB 8191
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Number, max.4096; Number range: 1 to 16000
Size, max.64 Kibyte
Retentivity adjustableYes; via non-retain property on DB
Retentivity presetYes
Local data
per priority class, max.32768 byte; Max. 2048 bytes per block
Address area
I/O address area
Inputs8192 byte
Outputs8192 byte
of which, distributed
Inputs8192 byte
Outputs8192 byte
Process image
Inputs8192 byte
Outputs8192 byte
Inputs, adjustable8192 byte
Outputs, adjustable8192 byte
Inputs, default1024 byte
Outputs, default1024 byte
Subprocess images
Number of subprocess images, max.1; With PROFINET IO, the length of the user data is limited to 1600 bytes
Digital channels
Inputs65536
Outputs65536
Inputs, of which central1024
Outputs, of which central1024
Analog channels
Inputs4096
Outputs4096
Inputs, of which central256
Outputs, of which central256
Hardware configuration
Racks, max.4
Modules per rack, max.8
Number of DP masters
integrated2
via CP4
Number of operable FMs and CPs (recommended)
FM8
CP, point-to-point8
CP, LAN10
Time of day
Clock
Hardware clock (real-time clock)Yes
battery-backed and synchronizableYes
Deviation per day, max.10 s; Typ.: 2 s
Backup time6 wk; At 40 °C, ambient temperature
Behavior of the clock following POWER-ONClock continues running after POWER OFF
Behavior of the clock following expiry of backup periodClock continues to run with the time at which the power failure occurred
Operating hours counter
Number4
Number/Number range0 to 3
Range of values0 to 2^31 hours (when using SFC 101)
Granularity1 hour
retentiveYes; Must be restarted at each restart
Clock synchronization
supportedYes
to MPI, masterYes
to MPI, slaveYes
to DP, masterYes; With DP slave only slave clock
to DP, slaveYes
in AS, masterYes
in AS, slaveYes
on Ethernet via NTPYes; as client
1st interface
Type of interfaceIntegrated RS 485 interface
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.150 mA
Functionality
MPIYes
DP masterYes
DP slaveYes
Point-to-point connectionNo
MPI
Services
PG/OP communicationYes
RoutingYes
Global data communicationYes
S7 basic communicationYes
S7 communicationYes
S7 communication, as clientNo; but via CP and loadable FB
S7 communication, as serverYes
Transmission rate, max.12 Mbit/s
DP master
Services
PG/OP communicationYes
RoutingYes
Global data communicationNo
S7 basic communicationYes; I blocks only
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes
Equidistance mode supportYes
Isochronous modeNo
SYNC/FREEZEYes
Activation/deactivation of DP slavesYes
Number of DP slaves that can be simultaneously activated/deactivated, max.8
Direct data exchange (slave-to-slave communication)Yes; As subscriber
DPV1Yes
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.124
Address area
Inputs, max.8 Kibyte
Outputs, max.8 Kibyte
User data per DP slave
Inputs, max.244 byte
Outputs, max.244 byte
DP slave
Services
PG/OP communicationYes
RoutingYes; with interface active
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes; Connection configured on one side only
Direct data exchange (slave-to-slave communication)Yes
DPV1No
Transmission rate, max.12 Mbit/s
Automatic baud rate searchYes; only with passive interface
Transfer memory
Inputs244 byte
Outputs244 byte
Address area, max.32
User data per address area, max.32 byte
2nd interface
Type of interfaceIntegrated RS 485 interface
PhysicsRS 485
IsolatedYes
Power supply to interface (15 to 30 V DC), max.200 mA
Functionality
MPINo
DP masterYes
DP slaveYes
PROFINET IO ControllerNo
PROFINET IO DeviceNo
PROFINET CBANo
Open IE communicationNo
Web serverNo
DP master
Services
PG/OP communicationYes
RoutingYes
Global data communicationNo
S7 basic communicationYes; I blocks only
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes; Connection configured on one side only
Equidistance mode supportYes
Isochronous modeYes; OB 61 - isochronous mode is possible either on DP or PROFINET IO (not simultaneously)
SYNC/FREEZEYes
Activation/deactivation of DP slavesYes
Number of DP slaves that can be simultaneously activated/deactivated, max.8
Direct data exchange (slave-to-slave communication)Yes; As subscriber
DPV1Yes
Transmission rate, max.12 Mbit/s
Number of DP slaves, max.124
Address area
Inputs, max.8 Kibyte
Outputs, max.8 Kibyte
User data per DP slave
Inputs, max.244 byte
Outputs, max.244 byte
DP slave
Services
PG/OP communicationYes
RoutingYes; with interface active
Global data communicationNo
S7 basic communicationNo
S7 communicationYes
S7 communication, as clientNo
S7 communication, as serverYes; Connection configured on one side only
Direct data exchange (slave-to-slave communication)Yes
DPV1No
GSD fileThe latest GSD file is available at: http://www.siemens.de/profibus-gsd
Transmission rate, max.12 Mbit/s
Automatic baud rate searchYes; only with passive interface
Transfer memory
Inputs244 byte
Outputs244 byte
Address area, max.32
User data per address area, max.32 byte
3rd interface
Type of interfacePROFINET
PhysicsEthernet RJ45
IsolatedYes
Integrated switchYes
Number of ports2
Automatic detection of transmission speedYes; 10/100 Mbit/s
AutonegotiationYes
AutocrossingYes
Media redundancy
supportedYes
Switchover time on line break, typically200 ms; PROFINET MRP
Number of stations in the ring, max.50
Change of IP address at runtime, supportedYes
Functionality
MPINo
DP masterNo
DP slaveNo
PROFINET IO ControllerYes; Also simultaneously with I-Device functionality
PROFINET IO DeviceYes; Also simultaneously with IO Controller functionality
PROFINET CBAYes
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Web serverYes
Number of HTTP clients5
PROFINET IO Controller
Services
PG/OP communicationYes
RoutingYes
S7 communicationYes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
Isochronous modeYes; OB 61 - isochronous mode is possible either on DP or PROFINET IO (not simultaneously)
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
Transmission rate, max.100 Mbit/s
Number of connectable IO devices, max.256
Max. number of connectable IO devices for RT256
of which in line, max.256
Number of IO devices with IRT and the option "high flexibility"256
of which in line, max.61
Number of IO Devices with IRT and the option "high performance", max.64
of which in line, max.64
Shared device, supportedYes
Prioritized startup supportedYes
Number of IO Devices, max.32
Activation/deactivation of IO DevicesYes
Number of IO Devices that can be simultaneously activated/deactivated, max.8
IO Devices changing during operation (partner ports), supportedYes
Max. number of IO devices per tool8
Device replacement without swap mediumYes
Send cycles250 us, 500 us,1 ms; 2 ms, 4 ms (not in the case of IRT with "high flexibility" option)
Updating time250 μs to 512 ms (depending on the operating mode, see Manual "S7-300 CPU 31xC and CPU 31x, Technical Data" for more details)
Address area
Inputs, max.8 Kibyte
Outputs, max.8 Kibyte
User data per address area, max.
User data consistency, max.1024 byte
PROFINET IO Device
Services
PG/OP communicationYes
RoutingYes
S7 communicationYes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32
Isochronous modeNo
Open IE communicationYes; Via TCP/IP, ISO on TCP, and UDP
IRT, supportedYes
PROFIenergy, supportedYes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device
Shared device, supportedYes
Number of IO controllers with shared device, max.2
Transfer memory
Inputs, max.1440 byte; Per IO Controller with shared device
Outputs, max.1440 byte; Per IO Controller with shared device
Submodules
Number, max.64
User data per submodule, max.1024 byte
PROFINET CBA
acyclic transmissionYes
Cyclic transmissionYes
Open IE communication
Open IE communication, supportedYes
Number of connections, max.32
Local port numbers used at the system end0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535
Keep-alive function, supportedYes
Isochronous mode
Isochronous modeYes; Via 2nd PROFIBUS DP or PROFINET interface
Communication functions
PG/OP communicationYes
Data record routingYes
Global data communication
supportedYes
Number of GD loops, max.8
Number of GD packets, max.8
Number of GD packets, transmitter, max.8
Number of GD packets, receiver, max.8
Size of GD packets, max.22 byte
Size of GD packet (of which consistent), max.22 byte
S7 basic communication
supportedYes
User data per job, max.76 byte
User data per job (of which consistent), max.76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server)
S7 communication
supportedYes
as serverYes
as clientYes; via integrated PROFINET interface and loadable FB or via CP and loadable FB
User data per job, max.See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication)
S5-compatible communication
supportedYes; via CP and loadable FC
Open IE communication
TCP/IPYes; via integrated PROFINET interface and loadable FBs
Number of connections, max.32
Data length for connection type 01H, max.1460 byte
Data length for connection type 11H, max.32768 byte
ISO-on-TCP (RFC1006)Yes; via integrated PROFINET interface and loadable FBs
Number of connections, max.32
Data length, max.32768 byte
UDPYes; via integrated PROFINET interface and loadable FBs
Number of connections, max.32
Data length, max.1472 byte
Web server
supportedYes
Number of HTTP clients5
User-defined websitesYes
PROFINET CBA (at set setpoint communication load)
Setpoint for the CPU communication load20 %
Number of remote interconnection partners32
Number of functions, master/slave50
Total of all Master/Slave connections3000
Data length of all incoming connections master/slave, max.24000 byte
Data length of all outgoing connections master/slave, max.24000 byte
Number of device-internal and PROFIBUS interconnections1000
Data length of device-internal und PROFIBUS interconnections, max.8000 byte
Data length per connection, max.1400 byte
Remote interconnections with acyclic transmission
Sampling frequency: Sampling time, min.200 ms
Number of incoming interconnections100
Number of outgoing interconnections100
Data length of all incoming interconnections, max.3200 byte
Data length of all outgoing interconnections, max.3200 byte
Data length per connection, max.1400 byte
Remote interconnections with cyclic transmission
Transmission frequency: Transmission interval, min.1 ms
Number of incoming interconnections300
Number of outgoing interconnections300
Data length of all incoming interconnections, max.4800 byte
Data length of all outgoing interconnections, max.4800 byte
Data length per connection, max.450 byte
HMI variables via PROFINET (acyclic)
Number of stations that can log on for HMI variables (PN OPC/iMap)3; 2x PN OPC/1x iMap
HMI variable updating500 ms
Number of HMI variables600
Data length of all HMI variables, max.9600 byte
PROFIBUS proxy functionality
supportedYes
Number of linked PROFIBUS devices32
Data length per connection, max.240 byte; Slave-dependent
Number of connections
overall32
usable for PG communication31
reserved for PG communication1
Adjustable for PG communication, min.1
Adjustable for PG communication, max.31
usable for OP communication31
reserved for OP communication1
adjustable for OP communication, min.1
adjustable for OP communication, max.31
usable for S7 basic communication30
Reserved for S7 basic communication0
adjustable for S7 basic communication, min.0
adjustable for S7 basic communication, max.30
usable for S7 communication16
reserved for S7 communication0
Adjustable for S7 communication, min.0
Adjustable for S7 communication, max.16
Max. total number of instances32
usable for routingX1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as DP master: max. 24; X2 as DP slave (active): max. 14; X3 as PROFINET: 48 max.
S7 message functions
Number of login stations for message functions, max.32; Depending on the configured connections for PG/OP and S7 basic communication
Process diagnostic messagesYes
simultaneously active Alarm-S blocks, max.300
Test commissioning functions
Status/control
Status/control variableYes
VariablesInputs, outputs, memory bits, DB, times, counters
Number of variables, max.30
of which status variables, max.30
of which control variables, max.14
Forcing
ForcingYes
Force, variablesInputs, outputs
Number of variables, max.10
Status blockYes; Up to 2 simultaneously
Single stepYes
Number of breakpoints4
Diagnostic buffer
presentYes
Number of entries, max.500
adjustableNo
Of which powerfail-proof100
Number of entries readable in RUN, max.499
adjustableYes; From 10 to 499
preset10
Service data
Can be read outYes
Ambient conditions
Operating temperature
Min.0 °C,
max.60 °C,
Configuration
Configuration software
STEP 7Yes; V5.5 or higher
programming
Programming language
LADYes
FBDYes
STLYes
SCLYes
CFCYes
GRAPHYes
HiGraph®Yes
Command setsee instruction list
Nesting levels8
Software libraries
System functions (SFC)see instruction list
System function blocks (SFB)see instruction list
Know-how protection
User program protection/password protectionYes
Block encryptionYes; With S7 block Privacy
Dimensions
Width120 mm
Height125 mm
Depth130 mm
Weight
Weight, approx.1250 g