6ES7314-1AE84-0AB0 SIMATIC S7-300, CPU 314
- Weight:
- 0.45kg
Product InformationSIMATIC S7-300, CPU 314 FOR EXPANDED TEMPERATURE RANGE INTEGRATED 24 V DC POWER SUPPLY 24 KBYTE WORKING MEMORY | Supply voltage | Rated voltage/DC | 24 V | permissible range, lower limit (DC) | 20.4 V | permissible range, upper limit (DC) | 28.8 V | Input current | Rated value at 24 V DC | 1000 mA | Inrush current, max. | 8 A | Power losses | Power loss, max. | 8 W | Memory | Work memory | integrated | 24 Kibyte; 24 KB/8 K instructions RAM (integrated); 1 instruction means 3 bytes on average | Load memory | expandable FEPROM | Yes; Flash-EPROM | expandable FEPROM, max. | 4 Mbyte | integrated RAM, max. | 40 Kibyte | Backup | present | Yes | with battery | Yes; all blocks | without battery | Yes; 4 KB: bit memory, counter, times and data | CPU processing times | for bit operations, min. | 0.3 µs | for bit operations, max. | 0.6 µs | for word operations, min. | 1 µs | for fixed point arithmetic, min. | 2 µs | for floating point arithmetic, min. | 50 µs | for timer/counter operations, min. | 12 µs | CPU-blocks | DB | Number, max. | 127 | Size, max. | 8 Kibyte | FB | Number, max. | 128 | Size, max. | 8 Kibyte | FC | Number, max. | 128 | Size, max. | 8 Kibyte | OB | Description | see instruction list | Size, max. | 8 Kibyte | Number of free cycle OBs | 1; OB 1 | Number of time alarm OBs | 1; OB 10 | Number of time interrupt OBs | 1; OB 35 | Number of process alarm OBs | 1; OB 40 | Number of startup OBs | 1; OB 100 | Nesting depth | per priority class | 8 | Counters, timers and their retentivity | S7 counter | Number | 64 | of which retentive with battery | adjustable | Yes | lower limit | 0 | upper limit | 63 | of which retentive without battery | adjustable | Yes | lower limit | 0 | upper limit | 63 | Counting range | lower limit | 1 | upper limit | 999 | S7 times | Number | 128 | of which retentive with battery | adjustable | Yes | lower limit | 0 | upper limit | 127 | of which retentive without battery | adjustable | Yes | lower limit | 0 | upper limit | 127 | Time range | lower limit | 10 ms | upper limit | 9990 s | Data areas and their retentivity | Flag | Number, max. | 256 byte | Retentivity available | Yes; MB 0 to MB 255 | of which retentive with battery | 0 to 2047 (M 0.0 to M 255.7, adjustable) | of which retentive without battery | 0 to 2047 (M 0.0 to M 255.7, adjustable) | Address area | I/O address area | Inputs | 512 byte | Outputs | 512 byte | Process image | Inputs | 128 byte | Outputs | 128 byte | Digital channels | Inputs | 1024 | Outputs | 1024 | Analog channels | Inputs | 256 | Outputs | 128 | Addressing volume | Outputs | 122 byte | Inputs | 122 byte | Hardware configuration | Modules per rack, max. | 32 | Expansion devices, max. | 3 | Connectable programming devices/PCs | PGs/PCs with STEP 7 connectable via MPI interface | Number of modules per DP slave interface, max. | 16 | Number of DP masters | integrated | 0 | via CP | 1; CP 342-5 | Number of operable FMs and CPs (recommended) | FM | 4 | CP, point-to-point | 2 | CP, LAN | 1 | Time of day | Clock | Hardware clock (real-time clock) | Yes | Interfaces | MPI | Cable length, max. | 9100 m; without repeaters: 50 m; with 2 repeaters: 1100 m; with 10 repeaters in series: 9100 m; via fiber optic cable: 23.8 km (with 16 star hubs or OLMs) | 1st interface | Functionality | MPI | Yes | MPI | Services | PG/OP communication | Yes | Global data communication | Yes | S7 basic communication | Yes | S7 communication | Yes | Number of nodes, max. | 32; 32 nodes on MPI bus; PG/PC, OP, additional S7-300/400, C7; per CPU max. 4 static and 4 dynamic connections | Transmission rate, max. | 187.5 kbit/s | Communication functions | PG/OP communication | Yes | Global data communication | supported | Yes | S7 basic communication | supported | Yes | S7 communication | supported | Yes | as server | Yes | S5-compatible communication | supported | Yes; via loadable blocks | Standard communication (FMS) | supported | Yes; via loadable blocks | Number of connections | overall | | of which dynamic | 8 | of which static | 4 | Configuration | Configuration software | STEP 7 | Yes; V5.0, V5.0 SP1 | programming | Programming language | LAD | Yes | FBD | Yes | STL | Yes | SCL | Yes | GRAPH | Yes | Command set | Binary logic operations, bracketed operations, result allocation, saving, counting, loading, transferring, comparing, shifting, rotating, complementation, calling blocks, fixed point arithmetic, floating point arithmetic, jump functions | Nesting levels | 8 | Program organization | Linear, structured | Software libraries | Process diagnostics | Yes | Software controller | Yes; depending on the required memory space and the resulting execution time | System functions (SFC) | Interrupt and error processing, copy data, clock functions, diagnostic functions, module parameterization, operating mode transitions | System function blocks (SFB) | 1 | Know-how protection | User program protection/password protection | Yes | Cycle time monitoring | lower limit | 1 ms | upper limit | 6000 ms | adjustable | Yes | preset | 150 ms | Dimensions | Width | 80 mm | Height | 125 mm | Depth | 130 mm | Weight | Weight, approx. | 530 g; Memory card 16 g |
Target Price
Offer your acceptable price, and we may make you satisfied.Your Target Price
|