Your cart is empty

6ES7212-1BB23-0XB0 CPU 222, AC PS, 8DI DC/6DO RELAY

Manufacturer:
SIEMENS
Weight:
0.31kg
Product Range:
Automation Systems

Product Information

SIMATIC S7-200, CPU 222 COMPACT UNIT, AC POWER SUPPLY 8 DI DC/6 DO RELAY 4 KB CODE/2 KB DATA, PROFIBUS DP EXTENDABLE
Supply voltage
120 V ACYes
230 V ACYes
Line frequency
Frequency of the supply voltage63 Hz
Load voltage L+
Rated value (DC)24 V
permissible range, lower limit (DC)5 V
permissible range, upper limit (DC)30 V
Load voltage L1
Rated value (AC)100 V; 100 to 230 V AC
permissible range, lower limit (AC)5 V
permissible range, upper limit (AC)250 V
permissible frequency range, lower limit47 Hz
permissible frequency range, upper limit63 Hz
Input current
Inrush current, max.20 A; at 264 V
from supply voltage L1, max.140 mA; 20 to 70 mA (240 V); 40 to 140 mA (120 V); output current for expansion modules (5 V DC) 340 mA
Encoder supply
24 V encoder supply
24 VYes; Permissible range: 20.4 to 28.8 V
Short-circuit protectionYes; electronic at 600 mA
Output current, max.180 mA
Backup battery
Battery operation
Backup time, max.50 h; (min. 8 h at 40 °C); 200 days (typ.) with optional battery module
Memory
Number of memory modules (optional)1; pluggable memory module, content identical with integral EEPROM; can additionally store recipes, data logs and other files
Data and program memory
Data memory, max.2 Kibyte
Program memory, max.4 Kibyte
Backup
presentYes; Program: Entire program maintenance-free on integral EEPROM, programmable via CPU; data: Entire DB 1 loaded from PG/PC maintenance-free on integral EEPROM, current values of DB 1 in RAM, retentive memory bits, timers, counters, etc. maintenance-free via high-performance capacitor; optional battery for long-term buffering
CPU processing times
for bit operations, max.0.22 µs
Counters, timers and their retentivity
S7 counter
Number256
of which retentive with battery
adjustableYes; via high-performance capacitor or battery
lower limit1
upper limit256
Counting range
lower limit0
upper limit32767
S7 times
Number256
of which retentive with battery
adjustableYes; via high-performance capacitor or battery
upper limit64
Time range
lower limit1 ms
upper limit54 min; 4 timers: 1 ms to 30 s; 16 timers: 10 ms to 5 min; 236 timers: 100 ms to 54 min
Data areas and their retentivity
Flag
Number, max.32 byte
Retentivity availableYes; M 0.0 to M 31.7
of which retentive with battery0 to 255, via high-performance capacitor or battery, adjustable
of which retentive without battery0 to 112 in EEPROM, adjustable
Hardware configuration
Expansion devices, max.2; Only expansion modules of the S7-22x series can be used. Due to the limited output current, the use of expansion modules may be limited.
Connectable programming devices/PCsSIMATIC PG/PC, standard PC
Expansion modules
Analog inputs/outputs, max.10; max. 8 inputs and 2 outputs (EM) or max. 0 inputs and 4 outputs (EM)
Digital inputs/outputs, max.78; max. 40 inputs and 38 outputs (CPU + EM)
AS-Interface inputs/outputs max.62; AS-Interface A/B slaves (CP 243-2)
Digital inputs
Number/binary inputs8
m/p-readingYes; optionally, per group
Input voltage
Type of voltage / of the input voltage
Rated value, DC24 V
for signal "0"0 to 5 V
for signal "1"min. 15 V
Input current
for signal "1", typ.2.5 mA
Input delay (for rated value of input voltage)
for standard inputs
ParameterizableYes; all
at "0" to "1", min.0.2 ms
at "0" to "1", max.12.8 ms
for interrupt inputs
ParameterizableYes; I 0.0 to I 0.3
for counter/technological functions
ParameterizableYes; (E0.0 to E0.5) 30 kHz
Cable length
Cable length, shielded, max.500 m; Standard input: 500 m, high-speed counters: 50 m
Cable length unshielded, max.300 m; not for high-speed signals
Digital outputs
Number/binary outputs6; Relay
Functionality/short-circuit strengthNo; to be provided externally
Switching capacity of the outputs
with resistive load, max.2 A
on lamp load, max.30 W DC; 200 W AC
Output voltage
for signal "1", min.L+/L1
Output current
for signal "1" rated value2 A
for signal "0" residual current, max.0 mA
Output delay with resistive load
0 to "1", max.10 ms; all outputs
1 to "0", max.10 ms; all outputs
Parallel switching of 2 outputs
for increased powerNo
Aggregate current of outputs (per group)
Digital inputs / Number of inputs that can be driven in parallel / all mounting positions
up to 40 °C, max.6 A
horizontal installation
up to 55 °C, max.6 A
Relay outputs
Number of operating cycles10000000; mechanically 10 million, at rated load voltage 100,000
Cable length
Cable length, shielded, max.500 m
Cable length unshielded, max.150 m
Analog inputs
Number of analog potentiometers1; Analog potentiometer; resolution 8 bit
Encoder
Connectable encoders
2-wire BEROSYes
permissible quiescent current (2-wire BEROS), max.1 mA
1st interface
Type of interfaceIntegrated RS 485 interface
PhysicsRS 485
Functionality
MPIYes; As MPI slave for data exchange with MPI masters (S7-300/S7-400 CPUs, OPs, TDs, Push Button Panels); S7-200-internal CPU/CPU communication is possible in the MPI network with restrictions; transmission rates: 19.2/187.5 kbit/s
PPIYes; with PPI protocol for program functions, HMI functions (TD 200, OP), S7-200-internal CPU/CPU communication ; transmission rates 9.6/19.2/187.5 kbit/s
Serial data exchangeYes; As freely programmable interface with interrupt facility for serial data exchange with third-party devices with ASCII protocol transfer rates: 1.2 / 2.4 / 4.8 / 9.6 / 19.2 / 38.4 / 57.6 / 115.2 kbit/s; the PC/PPI cable can also be used as RS232/RS485 converter
MPI
Transmission rate, max.187.5 kbit/s
Transmission rate, min.19.2 kbit/s
Integrated Functions
Number of counters4; High-speed counters (30 kHz each), 32 bits (incl. sign), can be used as up/down counters or for connecting 2 incremental encoders with 2 pulse trains offset by 90° (max. 20 kHz (A/B counters)); parameterizable enable and reset input; interrupt facilities (incl. call of subroutine with any content) when the setpoint is reached; reversal in counting direction, etc.
Counter frequency (counter) max.30 kHz
Number of alarm inputs4; 4 rising edges and/or 4 falling edges
Galvanic isolation
Galvanic isolation digital inputs
between the channelsYes
between the channels, in groups of4
Galvanic isolation digital outputs
between the channelsYes; Relay
between the channels, in groups of3
Permissible potential difference
between different circuits500 V DC between 24 V DC and 5 V DC; 1500 V AC between 24 V DC and 230 V AC
Ambient conditions
Environmental conditionsFor further environmental conditions, see "Automation System S7-200, System Manual"
Operating temperature
vertical installation, min.0 °C
vertical installation, max.45 °C
horizontal installation, min.0 °C
horizontal installation, max.55 °C
Air pressure
permissible range, min.860 hPa
permissible range, max.1080 hPa
Relative humidity
Operation, min.5 %
Operation, max.95 %; RH class 2 in accordance with IEC 1131-2
Degree and class of protection
IP20Yes
Configuration
programming
Programming language
LADYes
FBDYes
STLYes
Command setBit logic instructions, compare instructions, timer instructions, counter instructions, clock instructions, transmissions instructions, table instructions, logic instructions, shift and rotate instructions, conversion instructions, program control instructions, interrupt and communications instructions, logic stack instructions, integer maths, floating-point math instructions, numerical functions
Program processingfree cycle (OB 1), interrupt-controller, time-controlled (1 to 255 ms)
Program organization1 OB, 1 DB, 1 SDB subroutines with/without parameter transfer
Number of subroutines, max.64
Know-how protection
User program protection/password protectionYes; 3-stage password protection
Connection method
Plug-in I/O terminalsNo
Dimensions
Width90 mm
Height80 mm
Depth62 mm
Weight
Weight, approx.310 g

7 Units in Stock


Call for Availability
Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange

Ask A Question

Additional Images