Your cart is empty

6ES7151-7AB00-0AB0 SIMATIC DP, IM151-7 CPU FO FOR

Manufacturer:
SIEMENS
Weight:
0.35kg
Product Range:
Automation Systems

Product Information

SIMATIC DP, IM151-7 CPU FO FOR ET200S, WORKING MEMORY 48KB ( FROM FW V1.13 ON), INTEGR. PROFIBUS DP INTERFACE (FO SIMPLEX CONNECTOR) AS DP SLAVE, W/O BATTERY
General information
[nicht versorgt: TAK_ABW067_001_000]
associated programming packageSTEP 7 V5.1 or higher
Supply voltage
24 V DCYes
permissible range, lower limit (DC)20.4 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes; against destruction
Input current
Inrush current, max.3.5 A
from supply voltage 1L+, max.250 mA
Output current
Current output to backplane bus (DC 5 V), max.700 mA
Power losses
Power loss, typ.4.5 W
Memory
Work memory
integrated48 Kibyte; as of FW V1.13 48 KB; previously 24 KB
expandableNo
Load memory
pluggable (MMC)Yes
pluggable (MMC), max.2 Mbyte
Data management on MMC (after last programming), min.10 a
CPU processing times
for bit operations, min.0.3 µs
for word operations, min.1 µs
for fixed point arithmetic, min.2 µs
for floating point arithmetic, min.20 µs
for timer/counter operations, min.12 µs
CPU-blocks
DB
Number, max.127
Size, max.8 Kibyte
FB
Number, max.128
Size, max.8 Kibyte
FC
Number, max.128
Size, max.8 Kibyte
OB
Size, max.8 Kibyte
Number of free cycle OBs1; OB 1
Number of time alarm OBs1; OB 10
Number of delay alarm OBs1; OB 20
Number of time interrupt OBs1; OB 35
Number of process alarm OBs1; OB 40
Number of startup OBs1; OB 100
Number of asynchronous error OBs4; OB 80, 82, 85, 86
Nesting depth
per priority class8
additional within an error OB4
Counters, timers and their retentivity
S7 counter
Number64
Retentivity
adjustableYes
lower limit0
upper limit63
presetZ 0 to Z 7
Counting range
adjustableYes
lower limit0
upper limit999
IEC counter
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
S7 times
Number128
Retentivity
adjustableYes
lower limit0
upper limit127
presetNo retentivity
Time range
lower limit10 ms
upper limit9990 s
IEC timer
presentYes
TypeSFB
NumberUnlimited (limited only by RAM capacity)
Data areas and their retentivity
retentive data area in total (incl. times, counters, flags), max.4736 byte
Flag
Number, max.256 byte
Retentivity availableYes; MB 0 to MB 255
Retentivity presetMB 0 to MB 15
Number of clock memories8; 1 memory byte
Data blocks
Number, max.127
Size, max.8 Kibyte
Retentivity adjustableYes
Local data
per priority class, max.1536 byte
Address area
I/O address area
Inputs1536 byte
Outputs1536 byte
of which, distributed
Inputs64 byte
Outputs64 byte
Process image
Inputs128 byte
Outputs128 byte
Digital channels
Inputs248
Outputs248
Analog channels
Inputs124
Outputs124
Addressing volume
Outputs244 byte
Inputs244 byte
Hardware configuration
Number of mounting rails that can be used1
Max. length of mounting railStation width: <= 1 m or < 2 m
Number of modules per system, max.63
Connectable programming devices/PCsPGs/OPs with STEP 7 connectable via PROFIBUS interface
Time of day
Clock
Software clockYes
Operating hours counter
Number0
Interfaces
Interfaces1 x MPI/PROFIBUS DP
Number of USB interfaces0
Number of parallel interfaces0
Number of 20 mA interfaces (TTY)0
Number of RS 232 interfaces0
Number of RS 422 interfaces0
Number of other hardware interfaces1
PROFIBUS DP
Node addresses1 to 125
Cable length, max.1000 m; 100 to 1000 m (depending on transmission speed), without repeaters
1st interface
IsolatedNo
Power supply to interface (15 to 30 V DC), max.80 mA
Functionality
DP slaveYes
DP slave
Number of connections11
Services
S7 communication, as clientYes
S7 communication, as serverYes
Direct data exchange (slave-to-slave communication)Yes
GSD filehttp://www.siemens.de/profibus-gsd
Transmission rate, max.12 Mbit/s
Test commissioning functions
Diagnostic buffer
presentYes
Number of entries, max.100
Ambient conditions
Operating temperature
Min.0 °C
max.60 °C
Degree and class of protection
Type of protectionIP20
Configuration
Configuration software
STEP 7 LiteYes; V2.0 or higher
programming
Programming language
SCLYes
Command setBinary logic operations, bracketed operations, result allocation, saving, counting, loading, transferring, comparing, shifting, rotating, complementation, calling blocks, fixed point arithmetic, floating point arithmetic, jump functions
Nesting levels8
Program organizationLinear, structured
Software libraries
Process diagnosticsYes
Software controllerYes; depending on the required memory space and the resulting execution time
System functions (SFC)Interrupt and error processing, copy data, clock functions, diagnostic functions, module parameterization, operating mode transitions
Know-how protection
User program protection/password protectionYes
Cycle time monitoring
lower limit1 ms
upper limit6000 ms
adjustableYes
preset150 ms
Dimensions
Width60 mm
Height119.5 mm
Depth75 mm
Weight
Weight, approx.200 g
internTechDB
Characteristics will be deleted after 2012-12-31
Product version
STEP 7Yes; as of V5.1

4 Units in Stock


Call for Availability
Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review

Customer Q&A Exchange

Ask A Question

Additional Images