SIMATIC DP, ELECTRONIC MODULE DIGITAL, FOR ET 200B, W=160MM, 16DI 24V DC, STANDARD |
Supply voltage |
24 V DC | Yes; L3+; value at t < 0.5 s: 35 V |
permissible range, lower limit (DC) | 18.5 V |
permissible range, upper limit (DC) | 30.2 V |
Input current |
Current consumption, typ. | 70 mA; from L3+; logic |
Current consumption, max. | 500 mA; from L3+; sensor |
I²t | 0.05 A²·s; with starting current inrush |
Encoder supply |
Output voltage | 18.5 to 30 V |
Output current, rated value | 0.5 A |
Power losses |
Power loss, typ. | 2.5 W |
Hardware configuration |
Rack |
Required terminal block | TB1/DC, TB1-4/DC, TB3/DC, TB3-4/DC |
Digital inputs |
Number/binary inputs | 16 |
Input voltage |
Type of voltage / of the input voltage | |
Rated value, DC | 24 V |
for signal "0" | -30 to +5 V |
for signal "1" | 13 to 30 V |
Input current |
for signal "1", typ. | 4 mA; At 24 V min. 2 mA |
Input delay (for rated value of input voltage) |
for standard inputs |
at "0" to "1", min. | 2 ms |
at "0" to "1", max. | 3.5 ms |
Cable length |
Cable length unshielded, max. | 100 m |
Encoder |
Connectable encoders |
2-wire BEROS | Yes |
permissible quiescent current (2-wire BEROS), max. | 1.5 mA |
Interfaces |
PROFIBUS DP |
Transmission rate, max. | 12 Mbit/s |
FREECE capability | Yes |
Communication functions |
Bus protocol/transmission protocol | PROFIBUS DP |
Interrupts/diagnostics/status information |
Diagnostics indication LED |
Bus fault BF (red) | Yes |
Run mode RUN (green) | Yes |
Status indicator digital input (green) | Yes |
Galvanic isolation |
between electronic block and PROFIBUS DP | Yes |
Galvanic isolation digital inputs |
Galvanic isolation digital inputs | No |
Ambient conditions |
Operating temperature |
horizontal installation, min. | 0 °C |
horizontal installation, max. | 60 °C; 40°C for other mountings |
Air pressure |
permissible range, min. | 795 hPa |
permissible range, max. | 1080 hPa |
Relative humidity |
Operation, min. | 15 % |
Operation, max. | 95 %; RH class 2 in accordance with IEC 1131-2 |
Vibrations |
Operation, checked according to IEC 60068-2-6 | Yes; IEC 68, Part 2-6; 10 to 57 Hz; (constant amplitude 0.075 mm); 57 to 150 Hz; (constant acceleration 1 g) |
Shock test |
checked according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27; half-sine, 15 g, 11 ms |
Degree and class of protection |
IP20 | Yes |
Connection method |
Inputs/outputs | Screw-type and spring-loaded terminals, permanent wiring; 3 and 4-wire connection |
Dimensions |
Width | 160 mm; EB and TB |
Height | 130 mm; EB and TB |
Depth | 60 mm; EB and TB |
Weight |
Weight, approx. | 600 g; EB and TB |