Your cart is empty

6ES7124-1FA00-0AB0 SIMATIC SC,ELECTRONIC SUBMODULE

Manufacturer:
SIEMENS
Weight:
0.025kg
Product Range:
Automation Systems

Product Information

SIMATIC SC,ELECTRONIC SUBMODULE 1 AO, +/-10V, 1..5V
Supply voltage
Rated value (DC)24 V
Reverse polarity protectionYes
Input current
from supply voltage L+, max.50 mA
Power losses
Power loss, max.1 W
Hardware configuration
Rack
Required terminal blockTB 16SC
Digital outputs
Load resistance range
lower limit1000 Ω; In the rated range of the output
Analog outputs
Number of analog outputs1
Voltage output, short-circuit protectionYes
Voltage output, short-circuit current, max.30 mA
Output ranges, voltage
1 to 5 VYes
-10 to +10 VYes
Connection of actuators
for voltage output 2-conductor connectionYes
for voltage output 4-conductor connectionYes
Load impedance (in rated range of output)
with voltage outputs, capacitive load, max.1 µF
Destruction limits against externally applied voltages and currents
Voltages at the outputs towards MANA15 V; max. 15 V continuous; 75 V for max. 1 s (mark to space ratio 1:20)
Current, max.50 mA; DC
[nicht versorgt: TAK_ABT299_001_000]
Cable length, shielded, max.200 m
Analog value creation
Integrations and conversion time/ resolution per channel
Resolution (incl. overrange)S7 representation: +/-10 V, 1 to 5 V; S5 representation: 12 bits, 11 bits
Resolution with overrange (bit including sign), max.12 bit
Conversion time (per channel)5 ms
Settling time
for resistive load0.1 ms
for capacitive load3.3 ms
Errors/accuracies
Linearity error (relative to output area)+/- 0,06 %
Temperature error (relative to output area)+/- 0,01 %/K
Repeat accuracy in settled status at 25 °C (relative to output area)+/- 0,1 %
Operational limit in overall temperature range
Voltage, relative to output area+/- 0,9 %
Basic error limit (operational limit at 25 °C)
Voltage, relative to output area+/- 0,6 %
Interference voltage suppression for f = n x (fl +/- 1%), fl = interference frequency
Common mode interference (UCM < Vss AC (50 Hz)), min.30 dB
Interrupts/diagnostics/status information
Substitute values connectableNo
Alarms
AlarmsNo
Diagnostic alarmNo
Galvanic isolation
Galvanic isolation analog outputs
between the channels and the backplane busNo; Optocoupler
between the channels and the power supply of the electronicsNo
Permissible potential difference
between reference point of load and QV-(UCM)2 V DC / 2 Vpp AC
Isolation
Isolation checked with1500 V AC
Dimensions
Width20 mm
Height64 mm
Depth51 mm
Required slots2; from 8
Weight
Weight, approx.25 g

1 Units in Stock


Call for Availability
Price for:  EachMinimum:  1

Target Price

Offer your acceptable price, and we may make you satisfied.Your Target Price

Technical Support

Technical Support

Customer Reviews

Write Review